EL326 Installation Guide Rev 10-Feb-14
Page 29 of 33
POWER INPUT and ALARM OUTPUT
Dual-redundant internal power supplies (optional)
10-pole screw block can be positioned in front or back
Power input options:
o
+/-24-48 VDC (Doption)
(
absolute min and max:
+/-20-59 VDC)
o
+/-110-250 VDC or 100-240 VAC (50/60 Hz) A option
(
absolute min and max:
+/-90-300 VDC or 85-264
VAC (50/60 Hz)
Power consumption:
o
120 Watts typ. w/ all ports linked
Protection: current overload and reverse polarity
Alarm output: form-C relay (NO and NC contacts)
o
Max. voltage: 250 VAC, 30 VDC
o
Max. current: 2A @ 30 VDC or 250 VAC
MECHANICAL
Rack or wall mounting:
o
1U rack mount (19” brackets included)
o
Optional 23”, 24", EIA, WECO, ETSI and wall
brackets available
Ingress protection: IP50 sealed from dust and
contaminants
Heavy-gauge corrosion-resistant metal enclosure
Dimensions (HxWxD): 1.75(1U)x17.3x13
”
(45x439x330mm)
Weight (typical): 5.5 lbs (2.5 kg)
Routing Features
Host table: 8K
Route table: 8K
Static route table: 512
Multicast table: 1K
Unicast routing
o
Static unicast routes
o
RIP v1/v2
o
OSPF
o
BGP
Mulitcast routing
o
PIM-DM
o
PIM-SM
o
IGMP v1/v2/v3
o
IGMP v3 proxy
IP Redundancy
Proxy ARP
UDP Helper
ENVIRONMENTAL
Operating temperature: -35° to +80
˚C per IEC 60068-
2-1/2
DD/D0 models: -35° to +75°C per IEC 60068-2-1/2
Storage temperature: -40° to +8
5˚C
Cold startup: -35°C except with 10G module then -5°C
Humidity: 5 to 95% RH (non-condensing)
Vibration:
20mm/s from 1 to 150 Hz per IEEE 1613
Class V.S.3
Vibration:
Amp: 3mm from 2-9 Hz, 1g from 9-200Hz,
1.5g from 200-500 Hz per IEC 61850-3
Shock: 30g @ 11ms per IEC 61850-3
EMC and STANDARDS COMPLIANCE
EMC immunity: IEC 61850-3, IEC 61000-6-2/4, CE
EMC emissions: FCC Part 15;
EN 55022 (CISPR22), CE
Safety: UL508 /ANSI / ISA12.12.01 / CSA C22.2 No.
142 and No. 213
UL temperature specs: EL326-AA/AO-1, T4 @ 80C
EL326-DD/DO-1, T4 @ +75C
IEC61010-1, CE
RoHS, WEEE and CE compliant
ISO9001:2008 certified company
Warranty: 5 years on design and manufacturing
defects
MTBF A0/D0 models:
178,274
Hours GB @ 40˚C per
MIL-HNDBK-217F2
MTBF AA/DD models: 174,264
Hours GB @ 40˚C per
MIL-HNDBK-217F2
Содержание EL326
Страница 1: ...www redlion net EL326 Industrial Ethernet Managed Switch Installation Guide Revision 10 February 2014...
Страница 2: ...EL326 Installation Guide Rev 10 Feb 14 Page 2 of 33 This page intentionally left blank...