EL326 Installation Guide Rev 10-Feb-14
Page 14 of 33
Mounting
Brackets
There are many options for mounting these industrial Ethernet switches. Each switch is
supplied with a standard set o
f 19” rack mounting brackets. Optionally, mounting brackets for
23”, 24” and ETSI width racks are available. These mounting brackets universally support the
mounting hole spacing per the EIA (1.25”), ETSI (25mm) and WECO (1.00”) standards.
Refer to the mechanical diagram on the next page for details.
There are eight threaded inserts (see red arrows above) on each side of the switch that allow the brackets to be
mounted in numerous positions for the best fit in your rack. The brackets also have extra holes (see blue arrows
above) allowing them to be shifted right or left 1/2 inch. Use the supplied screws to mount the bracket in the desired
position. Plastic screws are also provided to plug the unused holes. See below for possible mounting positions.
In the image above, the brackets are mounted
flush with the front of the switch.
In the image above, the brackets are mounted so
the front of the switch is setback 1/2 inch.
For the most durable mounting you can use two brackets on each side (as shown in the image above). This is ideal
for applications requiring the highest shock and vibration resistance.