background image

1

3.80 (96.5)

1.95

(49.5)

.3

.10 (2.5)

(7.6)

4.20 (106.7)

1.75

(44.5)

3.62

1.77

(45     )

(92     )

+.03

-.00

+.8

-.0

+.02

-.00

+.6

-.0

 6-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY 

 CRYSTAL-CONTROLLED TIME-BASE PROGRAMMABLE UP TO 

32.764 SECONDS PROVIDES DIRECT-READING FOR ANY RATE 

UNITS

 0.02% ACCURACY

 PROGRAMMABLE DECIMAL POINTS

 FREQUENCY DOUBLING

 PROGRAMMABLE INPUT CIRCUIT, ACCEPTS OUTPUTS FROM A 

WIDE VARIETY OF SENSORS

 LEADING ZERO BLANKING

 POWER-UP SELF-TEST

 NEMA 4/IP65 SEALED FRONT METAL BEZEL

DESCRIPTION

The Apollo Time Base Rate Indicators (Model APLR) has the ability to scale 

for direct readout in terms of the units being measured. Whether a machine 

produces bottles, cloth, wire, or beverage mix, operation is enhanced when the 

rate readout is expressed directly in bottles/min., feet/min., gallons/hour, or 

whatever units are needed in plant operations. The APLR can provide this 

capability through its settable time base, programmable decimal points, and 

frequency doubling functions.

The APLR can also accommodate magnetic pickups, as well as logic 

(sourcing output)

 sensors and NPN open collector 

(sinking output)

 sensors.

This unit also has a self-test feature, which checks all the micro-processor 

and display driver circuitry after power-up 

(if enabled)

. This self-test also can 

be used to test the time base select DIP switches and decimal point select DIP 

switches, to make certain all switches are functioning properly.

Power and input connections are made via a removable terminal block, 

located at the rear of the unit. Each terminal can accept one #14 AWG wire. DIP 

switches at the side of the unit are used to program the input configuration.

The Apollo Rate Indicator has a sealed metal die-cast bezel which meets 

NEMA 4/IP65 specifications for wash-down and/or dust, when properly 

installed. Two mounting clips are provided for easy installation. The Time Base 

Rate Indicator uses a 6-digit, 0.56" (14.2 mm) high LED display, which is 

readable to 23 feet (7 M).

ORDERING INFORMATION

MODEL NO.

DESCRIPTION

PART NUMBER

APLR

Apollo Time Base Rate Indicator 

115 VAC

APLR0600

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

SPECIFICATIONS

1. 

DISPLAY:

 6-Digit, 0.56" (14.2 mm) high LED display. 

2. 

POWER REQUIREMENTS:

AC Operation

: 115 VAC, ±10%, 50/60 Hz, 14 VA

DC Operation

:

11 to 14 VDC @ 0.6 A max. Terminal #3 (+VDC) & #4 (common)

3. 

SENSOR POWER:

 +12 VDC, ±25% @ 100 mA max.

4. 

MAXIMUM OPERATING FREQUENCY:

 10 KHz, 50% duty cycle.

10,000 cps with min. pulse width 

“ON”

 and 

“OFF”

 times of 50 µsec.

5. 

TIME BASE SELECTION RANGE: 

0.004 to 32.764 seconds.

6. 

ACCURACY:

 0.02%

7. 

MAXIMUM INPUT VOLTAGE AND CURRENT: 

When the 

“SIG. IN”

 

(Terminal 5) is driven from external signal voltages, max. voltage swing is 

±50 V peak. Input voltage can be dropped by an external series resistance that 

limits input current to ±5 mA. 

(These ratings are for S3 “OFF”.)

MODELS APLR - APOLLO 6-DIGIT RATE INDICATOR [TIME BASE] 

 DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for 

         mounting clip installation is 2.1" (53.4) H x 5.5" (140) W. 

PANEL CUT-OUT

CAUTION: Risk of Danger.

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: Risk of electric shock.

Bulletin No.  APLR-P
Drawing No.  LP0118
Released  06/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

Содержание APLR

Страница 1: ...etal die cast bezel which meets NEMA 4 IP65 specifications for wash down and or dust when properly installed Two mounting clips are provided for easy installation The Time Base Rate Indicator uses a 6 digit 0 56 14 2 mm high LED display which is readable to 23 feet 7 M ORDERING INFORMATION MODEL NO DESCRIPTION PART NUMBER APLR Apollo Time Base Rate Indicator 115 VAC APLR0600 SAFETY SUMMARY All saf...

Страница 2: ... current sink output Sensor output must sink 4 mA VOL of 1 V or less DECIMAL POINT SELECTION The selection of Decimal Point is accomplished by DIP switches 4 and 5 The table at the right shows what combination of switches is needed to obtain the desired decimal point location The unit always has leading zero blanking Note D P will change only at the normal display update time of the unit REAR PANE...

Страница 3: ...act life b If a DC inductive load such as a DC relay coil is controlled by a transistor switch care must be taken not to exceed the breakdown voltage of the transistor when the load is switched One of the most effective ways is to place a diode across the inductive load Most RLC products with solid state outputs have internal zener diode protection However external diode protection at the load is ...

Страница 4: ...most RLC magnetic pickups has open shield on pickup end INSTALLATION ENVIRONMENT The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation Placing the unit near devices that generate excessive heat should be avoided The bezel should be cleaned only with a soft cloth and neutral soap product Do NOT use solvents Continuous exp...

Страница 5: ... know what the time is in seconds multiply 250 x 0 004 sec 1 sec Note This is the set up for a one second time base which allows for direct readout of RPM 1 800 x 1 x 15 000 1 800 x 60 FLOW RATE INDICATION APPLICATION A positive displacement pump is driven by a gear reducer and an AC motor The magnetic pickup which senses the gear in combination with the pump and reducer provides 560 pulses for ev...

Страница 6: ...s would be as follows TBIT Display Readout Desired x 10 x 15 000 TBIT 1336 DIP switch 11 1024 Needed 312 DIP switch 9 256 Needed 56 DIP switch 6 32 Needed 24 DIP switch 5 16 Needed 8 DIP switch 4 8 Now DIP switches 4 5 6 9 and 11 are set to ON Also the tenths position decimal point would be set to ON Note If the time base is now too long approximately 5 3 sec the FRQ DBL DIP switch can be set to O...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ...h Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those...