LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship 

for a period limited to two years from the date of shipment, provided the products have been stored, 

handled, installed, and used under proper conditions. The Company’s liability under this limited 

warranty shall extend only to the repair or replacement of a defective product, at The Company’s 

option. The Company disclaims all liability for any affirmation, promise or representation with 

respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against 

damages, claims, and expenses arising out of subsequent sales of RLC products or products 

containing components manufactured by RLC and based upon personal injuries, deaths, property 

damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be 

to any extent liable, including without limitation penalties imposed by the Consumer Product Safety 

Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty 

Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except 

those expressly contained herein. The Customer acknowledges the disclaimers and limitations 

contained herein and relies on no other warranties or affirmations.

Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls

China

Unit 302, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113 3688

Fax +86 21 6113 3683

Red Lion Controls

Europe

Softwareweg 9

NL - 3821 BN Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls

India

201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30

Gurgaon-122002 Haryana, India

Tel +91 984 487 0503

Содержание APLR

Страница 1: ...etal die cast bezel which meets NEMA 4 IP65 specifications for wash down and or dust when properly installed Two mounting clips are provided for easy installation The Time Base Rate Indicator uses a 6 digit 0 56 14 2 mm high LED display which is readable to 23 feet 7 M ORDERING INFORMATION MODEL NO DESCRIPTION PART NUMBER APLR Apollo Time Base Rate Indicator 115 VAC APLR0600 SAFETY SUMMARY All saf...

Страница 2: ... current sink output Sensor output must sink 4 mA VOL of 1 V or less DECIMAL POINT SELECTION The selection of Decimal Point is accomplished by DIP switches 4 and 5 The table at the right shows what combination of switches is needed to obtain the desired decimal point location The unit always has leading zero blanking Note D P will change only at the normal display update time of the unit REAR PANE...

Страница 3: ...act life b If a DC inductive load such as a DC relay coil is controlled by a transistor switch care must be taken not to exceed the breakdown voltage of the transistor when the load is switched One of the most effective ways is to place a diode across the inductive load Most RLC products with solid state outputs have internal zener diode protection However external diode protection at the load is ...

Страница 4: ...most RLC magnetic pickups has open shield on pickup end INSTALLATION ENVIRONMENT The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation Placing the unit near devices that generate excessive heat should be avoided The bezel should be cleaned only with a soft cloth and neutral soap product Do NOT use solvents Continuous exp...

Страница 5: ... know what the time is in seconds multiply 250 x 0 004 sec 1 sec Note This is the set up for a one second time base which allows for direct readout of RPM 1 800 x 1 x 15 000 1 800 x 60 FLOW RATE INDICATION APPLICATION A positive displacement pump is driven by a gear reducer and an AC motor The magnetic pickup which senses the gear in combination with the pump and reducer provides 560 pulses for ev...

Страница 6: ...s would be as follows TBIT Display Readout Desired x 10 x 15 000 TBIT 1336 DIP switch 11 1024 Needed 312 DIP switch 9 256 Needed 56 DIP switch 6 32 Needed 24 DIP switch 5 16 Needed 8 DIP switch 4 8 Now DIP switches 4 5 6 9 and 11 are set to ON Also the tenths position decimal point would be set to ON Note If the time base is now too long approximately 5 3 sec the FRQ DBL DIP switch can be set to O...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ...h Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those...