background image

1

3.80 (96.5)

1.95

(49.5)

.3

.1 (2.5)

(7.6)

4.20 (106.7)

1.75

(44.5)

3.62

1.77

(45    )

(92    )

+.03

-.00

+.8

-.0

+.02

-.00

+.6

-.0

1638

  

TWO MULTI-RANGE UNITS COVER:

199.9 µA to 1.999 A, 199.9 mV (DC)

1.999 V to 300 V (DC)

  

3 1/2-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY W/POLARITY

  BUILT-IN SCALING PROVISIONS

  SELECTABLE DECIMAL POINT LOCATION

  AUTO ZEROING CIRCUITS

  FRONT PANEL CALIBRATION ADJUSTMENT

  OVER-RANGE INDICATION

  NEMA 4/IP65 SEALED FRONT METAL BEZEL

DESCRIPTION

Apollo Volt and Current Meters are premium quality instruments designed 

for tough industrial applications. With multi-range capability, built-in provision 

for scaling, and DIP switch selectable decimal points, these units offer the 

ultimate in application flexibility. 

The die-cast metal bezel of the Apollo not only enhances the appearance of 

any panel, it can also be sealed in the front panel for use in wash-down areas and 

tough, dirty industrial environments. The 3 1/2-digit bi-polar display (minus sign 

displayed when current or voltage is negative) features 0.56" (14.2 mm) high, 

7-segment LED’s for easy reading. Also featured are removable terminal blocks 

on the rear that facilitate installation wiring and change-outs.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

SPECIFICATIONS

1. 

DISPLAY

: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment LED, (-) minus sign 

displayed when current or voltage is negative. Decimal points inserted before 

1st, 2nd, or 3rd least significant digits by DIP switch selection.

2. 

POWER

: 115 VAC ±10%, 50/60 Hz, 6 VA.

Isolation

: 2300 Vrms for 1 min. between input and supply.

3. 

INPUT RANGES

: (Selectable by input and jumper connections.)

DC Voltmeter 

DC Current Meter

±1.999 Volts (basic range) 

±199.9 µA

±19.99 Volts  

±1.999 mA

±199.9 Volts 

±19.99 mA

±300 Volts 

±199.9 mA

 

±1.999 amps

 

±199.9 mV (basic range)

Input Impedance:

Voltage

: All ranges1M

Current

: 199.9 µA 

1.111 K

 

1.999 mA 

111 

 

19.99 mA 

11 

 

199.9 mA 

 

1.999 A 

0.1 

4. 

ACCURACY

:

DC Volts

 - ±(0.1% of R 1 digit)

DC Current

199.9 µA, 1.999 mA, 19.99 mA

: ±(0.1% of R 1 digit)

199.9 mA

: ±(0.15% of R 1 digit)

1.999 A

: ±(0.5% of R 1 digit)

5. 

OVER-RANGE INDICATION

: on all modes is indicated by blanking 3 

least significant digits.

6. 

MAX. VOLTAGE ON BASIC RANGE INPUTS

: 75 VDC (Term. 8 to 3 on 

voltmeter, Term. 9 to 3 on current meter).

7. 

MAX. VOLTAGE ON TERMINAL BLOCK

: 300 VDC (Both voltmeter 

and current meter).

MODEL APLI - APOLLO CURRENT METER & MODEL APLV - APOLLO VOLTMETER

 DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for 

mounting clip installation is 2.1" (53.3) H x 5.5" (140) W. 

PANEL CUT-OUT

CAUTION: Risk of Danger.

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: Risk of electric shock.

Bulletin No.  APLI/V-K
Drawing No.  LP0123
Released  01/15

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

Содержание APLI

Страница 1: ...not specified by the manufacturer the protection provided by the equipment may be impaired SPECIFICATIONS 1 DISPLAY 3 1 2 digit 0 56 14 2 mm high 7 segment LED minus sign displayed when current or voltage is negative Decimal points inserted before 1st 2nd or 3rd least significant digits by DIP switch selection 2 POWER 115 VAC 10 50 60 Hz 6 VA Isolation 2300 Vrms for 1 min between input and supply ...

Страница 2: ...al radio transmitter Also Signal or Control cables within an enclosure should be routed as far away as possible from contactors control relays transformers and other noisy components 4 Long cable runs are more susceptible to EMI pickup than short cable runs 5 In extremely high EMI environments the use of external EMI suppression devices such as Ferrite Suppression Cores for signal and control cabl...

Страница 3: ...o the basic 0 to 1 999 V input range to get the desired reading The multi tap voltage divider provides coarse ranges of division and the scaling pot provides continuous selection of division factors between the taps Note The normal decade division factors 10 100 and 1000 have been adjusted in this schematic to account for parallel connection of the scale pot resistance which increases these factor...

Страница 4: ...sensitivity 199 9 mA since the 1 3 amp actual current exceeds the maximum current rating of this range See Specifications for maximum current 11 10 9 8 7 6 5 3 CW 900Ω 90Ω 9Ω 9Ω 0 1 999MA 0 19 99MA 0 1 999A 0 199 9MV BASIC INPUT BASIC VOLT METER CIRCUIT SCALE ADJ 4 COMM 1Ω 0 199 9µA TYPICAL RANGE SELECTION 0 120 0MA MAX DISPLAYED AS 0 100 SEE THE EXAMPLE AT RIGHT I 0 199 9MA INSTALLATION ENVIRONME...

Страница 5: ...r He replaces the access plug to keep dust out of the Apollo The Apollo voltmeter now indicates the oven temperature and the baker can monitor his temperature precisely 1 2 3 4 5 6 7 8 9 10 115 VAC 50 60HZ COMM 1000 100 10 V 1 999V IN SCALE ADJUST OVEN HIGH COMM SHIELD 375 THERMOMETER DIGITAL TEMPERATURE MONITORING IN A BISCUIT BAKING OPERATION TYPICAL VOLTAGE CURRENT MEASUREMENT APPLICATIONS VOLU...