1
3
14-FIRST IGNITION
Technical Dept. - All rights reserved - Reproduction prohibited
WARNINGS BEFORE IGNITION
GENERAL WARNINGS
Remove any objects that may burn from the brazier (manual, various adhesive labels or any polystyrene).
Check that the brazier is positioned correctly and rests properly on the base.
The first ignition may not be successful as the feed screw is empty and does not always manage to load the brazier
with the required amount of pellets in time to light the flame.
CANCEL THE FAILED IGNITION ALARM BY PRESSING AND HOLDING THE ON/OFF KEY FOR A FEW SECONDS. REMOVE THE
PELLETS LEFT IN THE BRAZIER AND REPEAT THE IGNITION.
SETTINGS TO BE CARRIED OUT BEFORE THE INITIAL START-UP/SHUTDOWN
Ignition
After connecting the power cable to the back of the product, turn the switch at the back to position(
I
). To turn the stove on or off, press
button
1
on the control panel.
The display on the panel will be ON with a flashing flame. When the flame stops blinking, the stove has reached the operating condition
to “supply power”.
The default factory set room temperature is 20°C. To change this setting, follow the instructions in the adjustments menu. Do the same
to set the heating water temperature and the speed of the ventilation fan (if required). To activate an external thermostat, if present, see
the dedicated paragraph.
SWITCHING THE EQUIPMENT OFF
To switch the equipment off, press the key 1 on the panel.
The equipment will start the shutdown process which involves consuming the residual pellets in the brazier, the latter being cleaned and
the residual heat in the structure being disposed of.
During the disposal phase of the residual heat, the fans operate at about 80% of their output and the speed cannot be varied. This is
determined by the need for all the accumulated heat to be evacuated safely and quickly. The shutdown stage can last 15 - 30 minutes
depending on the heat stored in the structure, determined by the duration and the operating speed of the product throughout the day.
When the internal temperature drops below the set thresholds, the hot air and exhaust fume extraction fans will automatically switch off.