Red Heating FRESIA 70 AIR 9 S1 Скачать руководство пользователя страница 3

1

3

14-FIRST IGNITION

Technical Dept. - All rights reserved - Reproduction prohibited

WARNINGS BEFORE IGNITION

GENERAL WARNINGS

Remove any objects that may burn from the brazier (manual, various adhesive labels or any polystyrene).

Check that the brazier is positioned correctly and rests properly on the base.

The first ignition may not be successful as the feed screw is empty and does not always manage to load the brazier 

with the required amount of pellets in time to light the flame.

CANCEL THE FAILED IGNITION ALARM BY PRESSING AND HOLDING THE ON/OFF KEY FOR A FEW SECONDS. REMOVE THE 

PELLETS LEFT IN THE BRAZIER AND REPEAT THE IGNITION.

SETTINGS TO BE CARRIED OUT BEFORE THE INITIAL START-UP/SHUTDOWN

Ignition

After connecting the power cable to the back of the product, turn the switch at the back to position(

I

). To turn the stove on or off, press 

button 

1

 on the control panel.

The display on the panel will be ON with a flashing flame. When the flame stops blinking, the stove has reached the operating condition 

to “supply power”.

The default factory set room temperature is 20°C. To change this setting, follow the instructions in the adjustments menu. Do the same 

to set the heating water temperature and the speed of the ventilation fan (if required). To activate an external thermostat, if present, see 

the dedicated paragraph.

SWITCHING THE EQUIPMENT OFF

To switch the equipment off, press the key 1 on the panel.

The equipment will start the shutdown process which involves consuming the residual pellets in the brazier, the latter being cleaned and 

the residual heat in the structure being disposed of.

During the disposal phase of the residual heat, the fans operate at about 80% of their output and the speed cannot be varied. This is 

determined by the need for all the accumulated heat to be evacuated safely and quickly. The shutdown stage can last 15 - 30 minutes 

depending on the heat stored in the structure, determined by the duration and the operating speed of the product throughout the day.

When the internal temperature drops below the set thresholds, the hot air and exhaust fume extraction fans will automatically switch off.

Содержание FRESIA 70 AIR 9 S1

Страница 1: ...INSTALLATION AND USER MANUAL EN INSERT FRESIA 70 AIR 9 S1 PART 2 OPERATION AND CLEANING Instructions in English...

Страница 2: ...ABLE OF CONTENTS II 14 FIRST IGNITION 3 15 CONTROL PANEL 5 16 MENU ITEMS AND OPERATION 6 17 SAFETY DEVICES 14 18 ALARMS 15 19 RECOMMENDATIONS FOR SAFE USE 20 20 CLEANING 21 21 FAULTS CAUSES SOLUTIONS...

Страница 3: ...the stove has reached the operating condition to supply power The default factory set room temperature is 20 C To change this setting follow the instructions in the adjustments menu Do the same to se...

Страница 4: ...ainconditions Itisgoodpracticetoensureeffectiveventilationintheroomduringtheinitialignition astheproductwillemitsome smokeandsmellofpaint Donotstandclosetotheproductandventilatetheroomasmentioned Thes...

Страница 5: ...eserved Reproduction prohibited KEY 1 Stove start up shutdown 2 Scrolling down through the programming menu 3 Menu 4 Scrolling up the programming menu 5 Decreases set temperature programming functions...

Страница 6: ...dashes Example TIMER 1Timer 1 program active TIMER 1 4Timer 1 and 4 programs active TIMER 1 2 3 4 5 6 All timer programs active EXAMPLE OF PROGRAMMING With the stove on or off access the MENU scroll t...

Страница 7: ...times of another program if the stove is already on the start has no effect while OFF turns off the stove When the stove is on and the timer is active pressing the OFF key turns off the stove The sto...

Страница 8: ...turns to the set values when the room temperature drops below the set threshold N B The point to the right of the room temperature on the control panel display indicates the half degrees e g 23 C is e...

Страница 9: ...o scroll through and select Settings Press menu to confirm Use the arrow keys to scroll through and select language Press menu to confirm Use the keys to select the required language IT EN DE FR ES NL...

Страница 10: ...de and time adjustment see paragraphs 8 f and 8 g respectively Theoption ECOstopt canbeadjustedtoensurecorrectoperationinthevariousenvironmentsinwhichthestovecanbeinstalledandto avoid constant shut do...

Страница 11: ...ckofdraughtorevenpressureintheduct itispossibletoincrease the smoke and ash extraction speed This change resolves all potential problems related to pellets clogged in the brazier and deposits forming...

Страница 12: ...Chimney sweeper Press the menu key Use the arrow keys to scroll through and select Settings Press menu to confirm Use the arrow keys to scroll through and select Chimney sweeper function Press menu to...

Страница 13: ...ed to the stove and the actual room temperature it provides Connect the cables coming from the external thermostat to terminal Term opt on board N100 on the stove Proceed as follows to enable the exte...

Страница 14: ...ng is reached TEMPORARY POWER OUTAGE When a power outage lasts less than 10 the stove returns to its previous operating state If it is longer it executes a cooling re ignition cycle FAILED START UP If...

Страница 15: ...uel to minimum SETTINGS menu Pellet recipe If the alarm persists contact the support centre Check whether the room fan is working correctly A04 Smoke overtemperature Reduce the load of pellets SETTING...

Страница 16: ...g the smoke extractor at minimum speed for 10 then proceeds to the next step 2 Restores the stove to the operating condition prior to the blackout During stage 1 the panel shows ON BLACK OUT During st...

Страница 17: ...The presence of a foreign body in the flue birds nests clogged grates etc Wind coming through the flue because it is unprotected or the installation was wall mounted or required no flue Cold air drau...

Страница 18: ...M 10 10 in Active System products RPM 30 50 in NON Active System products Thepercentagevariationaffectsallpowervalues 1to5 proportionallyandasapercentage Thepercentagevariationdoesnotaffect intermedia...

Страница 19: ...187 C 210 C Smoke temperature PLEASENOTETheindicatednegativepressurereadingsmaydifferby 1Pabasedonfluegastemperature Likewise fluegastemperature may differ by 10 C based on fuel quality or appliance...

Страница 20: ...product is installed in compliance with standards in force Furthermore it is of the utmost importance to comply with the following simple rules Every time the brazier is removed for cleaning it must...

Страница 21: ...ning Before ignition always clean the brazier b and remove any ash or incrustation from it that might obstruct the air flow holes paying attentiontohotash Inthecaseofignitionfailure oriffuelinthehoppe...

Страница 22: ...timal operating conditions of the component Cleaning the ash collection compartment Tocleantheashcollectioncompartment extracttheashpan P Removeanyresidualashbeforereinsertingthepan Yourexperienceand...

Страница 23: ...ucts often due to the quality of the fuel and the installation may cause the glass and chamber to become dirty morequickly Mainlytoimprovecleanlinessoftheglass wheretotalcleanlinesswillneverbepossible...

Страница 24: ...EPRODUCTISEXTRACTED When the movable part is put back in place make sure the machine is locked to the fixed part by closing the handle or the mechanicallock Basicversion Forgettingtodosomayresultinthe...

Страница 25: ...and dust in the ash pan and brazier zone Repeatedly pass it between the exchangers pipes arrow 2 in the figure to remove the fuel deposits and residues With the product extracted remove the screws z t...

Страница 26: ...ssembling the cast iron firebox panels it is advisable to vacuum the ash pan and brazier zone Also vacuum in the top part under the front grille to remove any accumulated dust Then thoroughly clean th...

Страница 27: ...uct where the fan outlet is located Also clean this compartment with a vacuum cleaner by inserting the nozzle on the fan inlet hole Then clean the smoke outlet system especially around the fittings cu...

Страница 28: ...askthespecialisedtechniciantorefreshthepaintinsidethecombustion chamber with the special silicone spray paints available at any store orTechnical Assistance Centre during the necessary annual end of...

Страница 29: ...ration consists of a visual and functional inspection of the internal components A summary of the checks and or maintenance operations that are essential for the correct operation of the product is pr...

Страница 30: ...ut is removed and switch the product back on If the problem persists contactTechnical Support The door is not closed properly or the gaskets are worn Closethedoorandreplacethegasketswith originalones...

Страница 31: ...n Replacethecontrolpanel The convection air fan never stops Faulty or malfunctioning temperature control probe Checktheprobeandreplaceit ifrequired In the automatic position the stove always runs at f...

Страница 32: ...TIAL CAUSES SOLUTIONS No increase in temperature with stove in operation Incorrect combustion adjustment Check recipe Set flame 1 setting level too low Increase power from the settings menu Poor pelle...

Страница 33: ...SENSOR 8 FEED SCREW 3 CONTROL PANEL 9 ROOM FAN 4 EXTERNALTHERMOSTAT OPTIONAL 10 SMOKE FAN 5 SMOKE ENCODER 11 AIR PRESSURE SWITCH DOOR SWITCH SWITCH PELLET LOADING HATCH 6 POWER SUPPLY 12 PELLET SAFETY...

Страница 34: ......

Страница 35: ......

Страница 36: ...04 09 2018 REV 0 8901845900 Via La Croce n 8 33074Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 997200 Internet www red365 it e mail info red365 it...

Отзывы: