X
28
20-CLEANING
PERIODICAL CHECK OF THE DOOR CLOSURE
Make sure the door closure ensures correct sealing (via the “paper sheet” test) and that when the door is closed, the closing block (X in the
figure) does not protrude from the sheet metal to which it is secured. For some products it will be required to disassemble the cladding to
be able to assess the anomalous protrusion of the block when the door is closed.
SHUTDOWN (end of season)
At the end of each season, before switching the product off, it is recommended to remove all pellets from the tank by using a vacuum
cleaner with a long pipe.
We recommend removing the unused pellets from the tank because it can retain moisture. Disconnect any combustion air ducting that
can lead moisture inside the combustion chamber but, above all, ask the specialised technician to refresh the paint inside the combustion
chamber with the special silicone spray paints (available at any store or Technical Assistance Centre) during the necessary annual end of
season scheduled maintenance operations. This way the paint will protect the inner parts of the combustion chamber, blocking any type
of oxidative process.
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again.
There is a fusebox on the back of the product, near the power socket. After having disconnected the plug from the socket, use a screwdriver
to open the cover of the fusebox and if necessary, replace them (3.15 A delayed) - by an authorised and qualified technician.
STOVE POWER SUPPLY
FUSE BOX