APPLY CAL
This will apply any of the performed calibrations. When selected, the Calibrate Apply screen will appear
asking you to confirm if you want to modify the camera’s sensor calibration.
Before performing the Calibrate Apply procedure, ensure the following is performed:
1. Ensure the lens cap is securely covering the sensor, preventing entry of any light source.
2. Ensure a properly formatted SSD is attached to the camera and properly formatted.
3. Select OK to perform the Calibrate Apply procedure. A status screen will appear showing progress in
percent.
4. When the Calibrate Apply procedure is complete, CALIBRATION COMPLETE will be displayed.
Select OK.
NOTE: If the Calibrate Apply procedure fails, APPLY CALIBRATION FAILED. TRY AGAIN will be
displayed. Perform the APPLY CALIBRATION procedure again.
SELF TEST
When selected allows you to perform a self-test for the sensor and LCD Touchscreen.
Version 1.4.0 SVN 29352 BETA
106
106
©2011 RED.COM INC.
APRIL 19, 2011