TESTING THE PIR
• Turn the SENS dial anti-clockwise to the maximum point, turn
the TIME dial clockwise to the minimum point, turn the
LUX dial clockwise to the Sun.
• When you switch on the power, the fitting will not illuminate.
After a 30 second pre-heat, when the sensor gets the
induction signal, the load will turn on. Once the load switches
off, it will then turn on again after 5-15 seconds of the sensor
receiving an induction signal.
• After the sensor goes off, trigger the detection field after
5-10 seconds. The load should work. When there is no
induction signals in the sensor, the load should stop working.
• Turn the LUX dial anti-clockwise to the Moon. If it
is adjusted to less than 3 LUX (dark), the load and sensor
should not work when testing in daylight. If you cover the
detection window with an opaque object, the load should
work. Under no induction signal condition, the load should
stop working within 5-15 seconds.
NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX
DIAL TO THE (SUN) POSITION, OTHERWISE THE SENSOR
WILL NOT WORK!
TROUBLESHOOTING
THE SENSITIVITY IS POOR:
• Please check if there are any objects in the detection field.
• Please check if the ambient temperature is too high.
• Please check if the installation height corresponds to the
height shown in the instructions.
FOR MODEL: FLAC10BPIR, FLAC10BPIR-31, FLAC20BPIR,
FLAC20BPIR-31, FLAC30BPIR, FLAC30BPIR-31, FLAC50BPIR &
FLAC50BPIR-31
LED AC DRIVERLESS
FLOODLIGHTS WITH PIR