TESTING THE PIR

• Turn the SENS dial anti-clockwise to the maximum point, turn  

   the TIME dial clockwise to the minimum point, turn the 

   LUX dial clockwise to the Sun.
• When you switch on the power, the fitting will not illuminate. 

   After a 30 second pre-heat, when the sensor gets the 

   induction signal, the load will turn on. Once the load switches 

   off, it will then turn on again after 5-15 seconds of the sensor 

   receiving an induction signal.
• After the sensor goes off, trigger the detection field after 

   5-10 seconds. The load should work. When there is no 

   induction signals in the sensor, the load should stop working.
• Turn the LUX dial anti-clockwise to the Moon. If it  

   is adjusted to less than 3 LUX (dark), the load and sensor 

   should not work when testing in daylight. If you cover the 

   detection window with an opaque object, the load should 

   work. Under no induction signal condition, the load should 

   stop working within 5-15 seconds.
NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX 

DIAL TO THE     (SUN) POSITION, OTHERWISE THE SENSOR 
WILL NOT WORK!

TROUBLESHOOTING

THE SENSITIVITY IS POOR:
• Please check if there are any objects in the detection field. 
• Please check if the ambient temperature is too high.
• Please check if the installation height corresponds to the 

  height shown in the instructions. 

FOR MODEL: FLAC10BPIR, FLAC10BPIR-31, FLAC20BPIR, 

FLAC20BPIR-31, FLAC30BPIR, FLAC30BPIR-31, FLAC50BPIR & 

FLAC50BPIR-31 