1. Open and remove Back Cover as instructed in OPENING AND CLOSING THE BACK
COVER.
2. Tip Housing backwards, gently sliding camera out of housing.
HANDLING PRECAUTIONS
The Lens Port lens is manufactured using hard coat acrylic. When cleaning use a clean soft
cloth taking care not to scratch it.
INTERNAL AND EXTERNAL STROBE
※
For heavy strobes and lights please use optional Grip & Tray Assembly and compatible
connector.
Fiber optic cable:
Connect fiber optic cable for external strobe use by inserting the bare fiber optic end into
Strobe Cable Port provided.
※
A single Tripod Sockets is provided at the bottom of the housing for use in attaching tray
and grip assemblies.
CAUTION! Seatool/Recsea STRONGLY recommends the use of Seatool/Recsea genuine
tray and grip assemblies listed below under OPTIONS. Leakage or damages due to the use
of non-genuine options are NOT covered under warranty.
Target Light:
The Accessory Shoe on top of the housing can be used for installation of a target light.
※
Please be mindful of the weight of the light you intend to use. For heavy lights and strobes
please use Seatool/Recsea genuine tray and grip assemblies.
※
Please refrain from using lights attached to the Accessory Shoe as a carrying handle.
CAUTION! Damage is irreparable.
MAINTENANCE
CAUTION!
Allowing saltwater and contaminants to dry on housing can damage functions and
O-rings possibly causing water leakage. Clean with fresh water only, using a soft, dry cloth to
wipe away water.
※
A complete housing overhaul is recommend once every year.
1. After use in salt water, wash off salt and other contaminants by soaking empty housing
thoroughly in a bucket of fresh water (lukewarm) for 10 to 20 minutes.
2. Manipulate all buttons and dials several times to flush out salt deposits and other
contaminants.
3. Wipe any water off housing with a soft dry cloth.
4. Open Back Cover and remove camera.
5. Using the O-ring Removal Pick, remove O-ring.
6. Clean O-ring Groove and O-ring contact surface using a clean cotton swab. DO NOT
clean housing or Lens Port with volatile organic solvents or chemical cleaning agents
such as thinner, gasoline, and benzine, etc.
7. Perform MAINTENANCE & O-RING GREASING as instructed below before re-installing.
O-RING GREASING & MAINTENANCE ( 1)
※
CAUTION!
DO NOT use silicone grease other than that provided by Seatool/Recsea.
4.
Содержание WHR-WG50 P
Страница 10: ...MEMO...