CAUTION! Seatool/Recsea STRONGLY recommends the use of Seatool/Recsea genuine
tray and grip assemblies listed below under OPTIONS. Leakage or damages due to the use
of non-genuine options are NOT covered under warranty.
MAINTENANCE
CAUTION!
Allowing saltwater and contaminants to dry on housing can damage functions and
O-rings possibly causing water leakage. Clean with fresh water only, using a soft, dry cloth to
wipe away water.
※
A complete housing overhaul is recommended once every year.
1. After use in salt water, wash off salt and other contaminants by soaking empty housing
thoroughly in a bucket of fresh water (lukewarm) for 10 to 20 minutes.
2. Manipulate all buttons and dials several times to flush out salt deposits and other
contaminants.
3. Wipe any water off housing with a soft dry cloth.
4. Perform O-RING GREASING & MAINTENANCE as instructed below before re-installing.
O-RING GREASING & MAINTENANCE ( 1)
※
CAUTION!
DO NOT use silicone grease other than that provided by Seatool/Recsea.
CAUTION!
This housing uses two (2) O-Rings, one (1) housing main body O-ring which
comes in contact with the housing main body Contact Surface shown below, and one (1) Port
O-ring. Please be sure to install the correct O-ring in the proper place. Failure to do so may
result in water leakage.
1. Using the O-ring Removal Pick, remove O-rings.
2. Clean sand, salt, other contaminants and old grease from O-rings.
3. Clean O-ring grooves and O-ring Contact Surfaces using a clean cotton swab.
6.