Malfunctions
46 / 48
BAL_K32_K42_ST_EN_1V2_REC_121-006454613
8.2
Function during a power failure
CAUTION
Danger of people being trapped inside the turnstile.
a) Bruises and contusions through from the turnstile wing.
ð
Visual inspection, check whether people are trapped inside.
In the event of a power failure, the rotation is stopped immediately and the turnstile is then freely ro-
tatable.
The key emergency operation button or start button are without function.
NOTICE
An emergency operation is only possible for a certain bridge period with an external (on-site)
or integrated UPS (Uninterruptible Power Supply).
If the system is equipped with a bistable electric turnstile lock, the turnstile remains locked in the basic
position in the operating mode LOCKED.
If a monostable closed lock is installed, the system is locked from any operating mode.