Operation
5
BAL_C127-SU-S_EN_1V1_REC_121-127401297
25 / 34
5.5
Description of parameters
W = Factory settings:
Basic drive
(FP)
PARAMETER
W
REMARK
DRIVING CYCLE
→ closing speed
18
Speed when closing the door.
0 = lowest speed
40 = highest speed
– The maximum speed depends on the opening angle and accelera-
tion.
→ Opening speed
36
Driving speed of the opening door.
0 = lowest speed
40 = highest speed
– The maximum reachable speed depends on the driven distance
(door width) and the acceleration setting.
– DIN: >1.5 s <4 s
TIME DELAY OPEN
→ time delay open
2
Determines how long the door remains open after it has been opened
by a trigger signal.
0..20 = 0 to 20 seconds, increment 1 s
21..40 = 22 to 60 seconds, increment 2 s
– The time delay open starts when all trigger and safety signals for
closing stop.
→ SSK time delay open
5
Determines the minimum time the door remains open after it has been
opened by a trigger signal of the type .
0..20 = 0 to 20 seconds, increment 1 s
21..40 = 22 to 60 seconds, increment 2 s
– The hold open time starts when all trigger and safety signals for
closing stop.
NOTICE
The open duration can be reduced when sensors are used which keep the door open, for ex-
ample
Time delay
.
OPERATOR
→ opening angle
35
The opening angle is determined during the teach-in run and corres-
ponds to the value 40.
0 = minimum opening angle
40 = maximum opening angle
–
DIN
: min. 95°