RM-216 CB.10 Easy Line Documentation
RDN 10000088
12
07.07.2016
8 Text messages on the display
Display
Explanation
Reset status and text version
The text message is displayed for approx. 1 second after the voltage is
switched on.
Reset RM204VXX
Controller is not enabled through inputs I1 and I2.
Stand By
+ - Val.No
The control has been enabled via input E1, E2 and stopped via input D1,
D2.
Cleaning Off
+ - Val.No
The control has been enabled via input E1, E2 and started via input D1,
D2.
Cleaning On
+ - Val.No
Down time cleaning active
DTC Cleaning ON
+ - 000 Pcs
The alarm switching point for the service hours counter has been
exceeded.
Call Service
+ - Val.No
A connected O module RM-LV8 or RM-LV16 is out of order.
or
the total number of valves (parameter P04) is set incorrectly.
RM-LVX Alarm
+ - Val.No