  Relative  humidity:  40%  to  75%.  Outside  of  these 

conditions,  the  product  must  only  be  used  for  a 
short time. 

  This product may not be  used to transport heavy 

objects. 

  There  must  be  a  flat  surface  of sufficient size  for 

the stool to be placed on. See 15. 

2.3. Storage & transport 

  Temperature  range:  5  °C  to  25  °C;  direct  radiant 

heat on the product must be avoided. 

  Store the product in dry rooms with a humidity of 

up to 65%. 

  The shower should be designed so that there is a 

flat surface of sufficient size. 

2.4. Equipment & functions 

 The chairs consist of a plastic frame on 4x

5“swivel 

castors  with  locking  brake.  The  armrests  can  be 
swivelled and have an armrest locking device. 

  The footrests are height adjustable and can be re-

moved or folded down. The headrest is height ad-
justable  and  rotatable.  A  tilt  adjustment  of  the 
chair, via  a  lever  function,  for the supine  position 
of the patient 

 Depending  on  the  equipment  variant,  there  is  a 

PUR seat for transport purposes or a PUR seat with 
hygiene cut-out (incl. toilet bucket with lid). 

 Due to the design and intended use of the product, 

disassembly for transport or storage is not intended 
or necessary. 

2.5. Packaging 

  We recommend you keep the packaging for a later 

transport. 

  Dimensions: 1005mm x 670mm x 900mm 

2.6. Disposal 

  Disposal and recycling of used products and pack-

aging must be carried out in accordance with cur-
rently valid regulations. Please contact a disposal 
company for further information. 

  The Infection Protection Act must be observed. 

  Please  observe  any  labels  and  information  on 

packaging material and act accordingly. 

3.  Symbols & nameplates 

 

Figure similar. 

The nameplate must not be removed! 

For  ordering  spare  parts  and  processing 

complaints,  the  device  name,  serial  number  and 
year of manufacture will be required. 

Symbol 

Meaning 

Symbol 

Meaning 

 

Read 

the 

manual! 

 

Year 

of 

manufac-
ture Device 

 

Serial  num-
ber 

 

Important 
information! 

 

Article num-
ber 

 

Maximum 
user  weight 
in kg 

 

Care 

in-

structions 

 

Mainte-
nance 

in-

structions 

 

Applicable 
for 

indoor 

use only. 

 

Manufac-
turer 

 

Visual  sig-
nal 

 

 

Language 

 

Read 

the 

User  Man-
ual! 

 

Do  not  dis-
pose  of  as 
household 
waste. 

 

Product complies with 

(EU) 2017/745 

MDR

 

 

Caution! 
Observe the safety instructions 

 

Unique Device Identifier 

(Data: GTIN / LOT (SN) / year of man-
ufacture) 

 

Medical device label 
This product is a medical device. 

4.  Safety instructions 

Please observe the following safety in-
structions: 

 

Before  using  the  device  for  the  first 

time, the User Manual must be read completely in 

EN 

Содержание 350.10 Series

Страница 1: ...135 2021 09 A01 Email info rebotec de Read this User Manual before using the device for the first time and keep it at hand for the user as well as for future use and subsequent sales EN User Manual Multifunctional nursing wheelchair Figure similar Phoenix PU Seat with hygiene cutout Phoenix PS Full seat 350 XX 10 350 XX 40 150 kg 150 kg XX colour code ...

Страница 2: ...p for use 6 9 1 Folding down the footrests 6 9 2 Adjusting the footrest height 6 9 3 Parking brake operation 6 9 4 Adjusting the headrest 6 9 5 Adjusting the height and depth 7 9 6 Adjusting the tilt angle 7 9 7 Adjusting the headrest inclination 7 10 Product data 8 11 Operation of the product 8 11 1 Sitting down 8 11 2 Swivelling down the armrests 8 11 3 Folding down the footrests 9 11 4 Removing...

Страница 3: ...ing down and going to the toilet even if a conventional toilet or bathroom is out of reach It can be infinitely adjusted between sitting and lying positions The patient must have sufficient sitting ability and upper body muscula ture If necessary a nurse must be present during use The product is not intended for prolonged sit ting and transfer Phoenix PS The product is intended for the care of pat...

Страница 4: ... is not intended or necessary 2 5 Packaging We recommend you keep the packaging for a later transport Dimensions 1005mm x 670mm x 900mm 2 6 Disposal Disposal and recycling of used products and pack aging must be carried out in accordance with cur rently valid regulations Please contact a disposal company for further information The Infection Protection Act must be observed Please observe any label...

Страница 5: ...in standstill and while moving If the swivel castors are in an unfa vourable position pointing inwards stability of the chair is limited Special care must be taken when moving the chair in a tilted position Caution Danger of breakage The chair is only suitable for the intended use Ob serve the permissible max body weight infor mation on the nameplate Caution Danger of pinching or catching When fol...

Страница 6: ...The reprocessing and maintenance instructions can be ordered or viewed and downloaded at www rebo tec de downloads 9 Setting up for use The product has been carefully inspected in the factory for freedom from defects and complete ness Please check the product for any possible damage which may have occurred during transport and for completeness of the scope of delivery upon receipt Assembly or adju...

Страница 7: ...can be adjusted by 12 degrees Pull the locking lever A vertically upwards and then press down on the backrest B to the desired position Push the locking lever C all the way down again Seat position Tilt position Maintenance instructions If operation of the locking lever is too stiff or too loose the clamping effect can be readjusted Dismantle the cover Using an Allen key SW5 the clamping effect of...

Страница 8: ...elves on the two armrests the patient should slowly sit down on the cushion If this is not possible due to their physical limita tions support must be provided by the nursing staff If necessary the use of a lifting aid or patient lift is advisable Caution Danger of falling Falling down or slumping on the chair seat must be avoided The patient should sit on the full chair surface if pos sible and n...

Страница 9: ...frame Now you can push the footrest all the way up and pull it out Clamp the cover back on 11 5 Removing the seats The seat with I and without O hygiene cut out the foot cushion K as well as the back cushion H can be removed from their locking mechanism on the chair frame for cleaning purposes or for re placement See description of the product page 3 11 6 Using the toilet bucket with lid When usin...

Страница 10: ... in structions 02 12 158 13 2 Maintenance Wear and tear that is not recognised in time and or improper handling as well as irregular or no maintenance may result in accidents For safety reasons the product must be pro fessionally maintained at least once a year Check product for visible damage cracks breaks loose parts Check stability before use Maintenance inspection scope Maintenance should incl...

Страница 11: ...440 10 14 PUR shower seat 5 440 10 24 PUR shower seat closed 6 450 10 16 PUR Backrest cushion 7 450 10 17 PUR Leg support 450 10 58 PUR Headrest standard 450 10 59 PUR headrest comfort 440 10 32 PUR Arm support 440 10 40 PUR Splash protection 02 07 135 User Manual 02 11 151 Maintenance log Only use REBOTEC spare parts and accessories to ensure proper and safe functioning of the device 1 2 3 4 5 6 ...

Страница 12: ...ll depth 1110 mm 1110 mm c2 Overall depth 1435 mm 1435 mm d Seat height 575 mm 565 mm Seat width 450 mm 450 mm e Width between armrests 540 mm 540 mm f Seat depth 440 mm 430 mm g Height to armrests 760 mm 760 mm h Knee height of footrest min 440 mm 430 mm Knee height of footrest max 520 mm 510 mm i Headrest height 120 mm 120 mm j1 Seat angle 103 103 j2 Lying angle 128 128 mm k Front castor diamete...

Отзывы: