REBOTEC /
BA-Nr.: 02.07.132/2021-11-A01
- 4 -
EN
3 Storage & transport
•
Temperature range: 5 °C to 25 °C; direct radiant
heat on the product must be avoided.
•
Store the product in dry rooms with a humidity of
up to 65%.
•
The shower should be designed so that there is a
flat surface of sufficient size.
3.1 Equipment & functions
•
The chairs consist of a plastic frame with a tube
insert. The self-propelled chair has two 5" wheels
with swivel castors at the front and two 24" wheels
with push rims and parking brake at the rear.
•
The armrests can be partially swivelled. The foot-
rests are height adjustable and can be removed or
folded down.
•
The seat contains a toilet-like recess under which
a toilet bucket with a lid can be inserted.
3.2 Packaging
•
We recommend you keep the packaging for a later
transport.
•
Dimensions: 740mm x 640mm x 640mm
3.3 Disposal
•
Disposal and recycling of used products and pack-
aging must be carried out in accordance with cur-
rently valid regulations. Please contact a disposal
company for further information.
•
The Infection Protection Act must be observed.
•
Please observe any labels and information on
packaging material and act accordingly.
4 Symbols & nameplates
Figure similar.
The nameplate must not be removed!
For ordering spare parts and processing
complaints, the device name, serial number and
year of manufacture will be required.
Symbol
Meaning
Symbol
Meaning
Read
the
manual!
Year
of
manufac-
ture of De-
vice
Serial num-
ber
Important
information!
Article num-
ber
Maximum
user weight
in kg
Care
in-
structions
Mainte-
nance
in-
structions
Applicable
for
indoor
use only.
Manufac-
turer
Visual sig-
nal
Language
Read
the
User Man-
ual!
Do not dis-
pose of as
household
waste.
Product complies with
(EU) 2017/745
MDR
Caution!
Observe the safety instructions
Unique Device Identifier
(Data: GTIN / LOT (SN) / year of man-
ufacture)
Medical device label
This product is a medical device.
5 Safety instructions
Please observe the following safety in-
structions:
•
Before using the device for the first time, the User
Manual must be read completely in order to avoid
hazards or damage caused by maloperation.
•
Before each use, check the device for visible dam-
age or deficiencies.
•
In case of malfunctions or damage of any kind, the
device must not be used.
Caution: Danger of falling!
•
The chair must only be used with the armrests
locked in place when sitting and moving about.
•
Sitting down, getting up, transferring of a patient
should done with the help of a trained caregiver,
depending on the patient's state of health.
EN