MAINTAIN REBAR STRAIGHTENER WITH
CARE
Inspect rebar straightener before each use. Faulty or
loose bending hook could possibly result in personal
injury. Keep handle dry, clean and free from oil and/
or grease. Keep housing and piston free of dirt and
iron filings. Check that no screws or bolts are loose
or missing. Follow all instructions for maintenance.
Inspect switch, cord, plug and any extension cable at
regular intervals.
STORE CAREFULLY
When not in use, store rebar straightener and its acces-
sories in a dry place where they cannot be accessed by
anyone but the operators.
PARTS AND SPECIFICATIONS (Figure 1)
1.
Handle
2.
Switch
3.
Mode control lever
4.
Oil plug
5.
Front handle
6.
Hook
7.
Roller
8.
Housing
9.
Motor
OPERATING INSTRUCTIONS
Check the oil level.
Check that the power source is appropriate to the rebar
straightener.
CARE- If voltage is too high, the motor will burn out,
if voltage is too low, insufficient power will be gener
-
ated.
NEVER USE DC CURRENT OR
AC HIGHER THAN 110V
Check that the power supply is properly earthed.
CAUTION- Failure to properly earth the power supply
may result in a shock to the operator.
Check that the cord is undamaged and that the plug is
not loose.
CAUTION- Cut or abraded covering could result in a
short and electric shock to the operator.
If an extension cord is to be used, make sure that it is
undamaged and that it is the proper thickness for the
length. See table below.
Before plugging the tool in, make sure that the switch
lock is off.
CAUTION- If switch lock is ON; the rebar straight-
ener will start as soon as it is plugged in. To disengage
lock, pull the trigger switch, the lock button will pop
out.
WARM UP
In cold weather, warm up the unit for 30-60 seconds
so that the hydraulic oil will reach the proper viscosity.
Pull the trigger switch to extend the piston and release
when it has reached its full stroke. Repeat this action
3-5 times.
POINTS OF ATTENTION
Do not cover air vents.
1.
CARE- If vents are covered, the motor will over-
2.
heat and may burn out.
If hydraulic oil exceeds 70*C, (158*F) the power
3.
will drop. Allow the unit to cool before resum-
100/115V
230V
Cable
Length
Cable Size
(AWG)
Nominal
Diameter
Up to 10m (33 ft.)
16
1.0mm2
Up to 15m (50 st.)
14
1.25mm2
Up to 30m (100ft.)
10
1.5mm2