6.7 Register 6 Auto-negotiation Expansion (ANER) 

This register contains additional status for NWay auto-negotiation.

 

Address 

Name 

Description/Usage 

Default/Attribute 

6:<15:5> Reserved 

Reserved:

 Ignore the output of the RTL8201L when these bits are read. 

This bit is always set to 0. 

 

6:<4> MLF 

Multiple Link Fault: 

Status indicating if a multiple link fault has 

occurred. Bit 4 is a read-only bit that gets latched high when a multiple 
link fault occurs in the Auto-negotiation state machine. For further 
details, please consult the IEEE standard. The bit is reset to ‘0’ after the 
register is read, or when the chip is reset.   
1: Fault occurred 
0: No fault occurred 

0, RO   

6:<3> LP_NP_ABLE 

Link Partner Next Page Able:

 Status indicating if the link partner 

supports Next Page negotiation. Bit 3 returns a ‘1’ when the Link 
Partner has Next Page capabilities. It has the same value as bit 15 of the 
Link Partner Ability Register.   
1: Supported 
0: Not supported 

0, RO   

6:<2> NP_ABLE 

Local Next Page Able:

 This bit indicates if the local node is able to 

send additional Next Pages. The RTL8201L does not have Next Page 
capabilities, so it will always return a ‘0’ when bit 2 is read.   

0, RO   

6:<1> PAGE_RX 

Page Received:

 This bit is set high when a new Link Code Word Page 

has been received from the Link Partner, checked and acknowledged. 
This bit is cleared when the link is lost or the chip is reset. It is 
automatically cleared when the auto-negotiation link partner’s ability 
register (register 5) is read by management. 

0, RO   

6:<0> LP_NW_ABLE 

Link Partner Auto-Negotiation Able:

 Bit 0 returns a ‘1’ when the 

Link Partner is known to have Auto-negotiation capabilities. Before any 
Auto-negotiation information is exchanged, or if the Link Partner does 
not comply with IEEE Auto-negotiation, the bit returns a value of ‘0’. 
1: Link partner supports Nway auto-negotiation 
0: Link partner does not support Nway auto-negotiation 

0, RO 

6.8 Register 16 Nway Setup (NSR) 

Address 

Name 

Description/Usage 

Default/Attribute 

16:<15:12> 

Reserved 

Ignore the results of these bits when read. 

 

16:<11> 

ENNWLE 

1: LED4 Pin indicates linkpulse 

0, RW   

16:<10> 

Testfun 

1: Auto-neg speeds up internal timer 

0, RW 

16:<9> 

NWLPBK 

1: Set Nway to loopback mode. 

0, RW 

16:<8:3> 

Reserved 

Ignore the results of these bits when read. 

 

16:<2> 

FLAGABD 

1: Auto-neg experienced ability detect state 

0, RO   

16:<1> 

FLAGPDF 

1: Auto-neg experienced parallel detection fault state 

0, RO   

16:<0> 

FLAGLSC 

1: Auto-neg experienced link status check state 

0, RO 

Tel: +49(0)234-9351135 · Fax: +49(0)234-9351137  

E-MAIL:

[email protected]

   http://www.

cornelius-consult.de

Содержание RTL8201(L)

Страница 1: ...X_ER Counter REC 15 6 11 Register1910MbpsNetworkInterfaceConfiguration 15 6 12 Register 20 PHY 1_1 15 6 13 Register 21 PHY 1_2 16 6 13 Register 22 PHY 2 16 6 14 Register 23 Twister_1 16 6 15 Register...

Страница 2: ...Interface interface Flow control ability support to co work with MAC by MDC MDIO 48 pin LQFP package 2 General Description The RTL8201 L is a single port Phyceiver with an MII Media Independent Inter...

Страница 3: ...l to Serial Baseline wander Correction 5B 4B Decoder Data Alignment Descrambler 4B 5B Encoder Scrambler 10 100 half full Switch Logic 10 100M Auto negotiation Control Logic Manchester coded waveform 1...

Страница 4: ...X2 33 TPTX 34 TPTX 28 RTSET 31 TPRX 30 TPRX 43 ISOLATE 40 RPTR RTT2 39 Speed 38 Duplex 37 ANE 41 LDPS 44 MII SNIB 9 LED0 PAD0 10 LED1 PAD1 12 LED2 PAD2 13 LED3 PAD3 15 LED4 PAD4 27 RTT3 VCTRL 42 RESET...

Страница 5: ...e Data These are the four parallel receive data lines aligned on the nibble boundaries driven synchronously to the RXC for reception by the external physical unit PHY RXER O 24 Receive error if any 5B...

Страница 6: ...Interface PHY Address Config Symbol Type Pin s No Description LED0 PAD0 O 9 Link LED LED1 PAD1 O 10 Full Duplex LED LED2 PAD2 O 12 Link 10 ACT LED LED3 PAD3 O 13 Link 100 ACT LED LED4 PAD4 O 15 Colli...

Страница 7: ...ompleted which requires approximately 1us Writing a 0 to this bit has no effect Because this bit is self clearing after a few cycles from a write operation it will return a 0 when read 1 Software rese...

Страница 8: ...1 Power down 0 Normal operation 0 RW 0 10 Reserved Reserved Ignore the output of the RTL8201L when these bits are read 0 9 Restart Auto Negotiation Restart Auto Negotiation Bit 9 is a self clearing b...

Страница 9: ...Base T half duplex mode If the chip is set to operate in this mode this bit will return a 1 when read 1 Enable 10Base T half duplex support 0 Suppress 10Base T half duplex support 1 RO 1 10 6 Reserved...

Страница 10: ...lity registers and will return a 1 when bit 0 is read Several extended registers have been implemented in the RTL8208 and their bit functions are defined later in this section 1 Extended register capa...

Страница 11: ...ility to the Link Partner that the RTL8201L can operate in 100Base T4 mode Writing a 0 to this bit will suppress the transmission of this ability to the Link Partner Resetting the chip will restore th...

Страница 12: ...ities of the Link Partner as received during Auto negotiation The content changes after the successful Auto negotiation if Next pages are supported Address Name Description Usage Default Attribute 5 1...

Страница 13: ...or the RTL8201L is reset 1 10Base T full duplex is supported by link partner 0 10Base T full duplex not supported by link partner 0 RO 5 5 10 10Base T This bit indicates that the Link Partner can supp...

Страница 14: ...O 6 1 PAGE_RX Page Received This bit is set high when a new Link Code Word Page has been received from the Link Partner checked and acknowledged This bit is cleared when the link is lost or the chip i...

Страница 15: ...causes a pre mature end error detection to be reported 0 RW 17 2 LINK_err Assertion of this bit causes a link error detection to be reported 0 RW 17 1 PKT_err Assertion of this bit causes a detection...

Страница 16: ...h test functions as RTL8139C 76 RO 22 7 0 PHY2_80 PHY2 register for PLL select functions as RTL8139C 80 R W 6 14 Register 23 Twister_1 Address Name Description Usage Default Attribute 23 15 0 TW_1 Twi...

Страница 17: ...d receive function While transmitting packets the MAC will first assert the TXEN signal and change byte data into 4 bits nibble and pass to the PHY by TXD 0 3 PHY will sample TXD 0 synchronously with...

Страница 18: ...EED DUX pins and their operation mode ANE SPEED DUX Operation H L L Auto negotiation enabled the ability field does not support 100Mbps or full duplex mode operation H L H Auto negotiation enabled the...

Страница 19: ...h is the default mode for the RTL8201 This pin pulled low will set the RTL8201 L into SNI mode operation When set to SNI mode the RTL8201 L will work at 10Mbps Please refer to the section covering Ser...

Страница 20: ...d PHY address configurations In the left figure the PHY address is set to 00001b 01h In the right figure the PHY address is set to 00010b 02h In the above two PHY address designs all useable LEDs have...

Страница 21: ...s configured by hardware pin 43 Setting pin 43 high will isolate the RTL8201 L from the Media Access Controller MAC and the MDC MDIO management interface In this mode power consumption is minimum 7 8...

Страница 22: ...using the RTL8201 L in a NIC or switch application please set the default mode NIC Switch mode is the default setting and has the RPTR pin pulled low or bit 15 of register 17 is set to 0 7 10 Reset P...

Страница 23: ...mode 8 mA PPWD Power down mode 6 mA PIsolate Isolate mode 5 mA P100F 100Base full duplex 99 mA P10F 10Base full duplex 129 mA P10TX 10Base transmit 127 mA P10RX 10Base receive 32 mA P10IDLE 10Base id...

Страница 24: ...on Without Collision Shown is an example transfer of a packet from MAC to PHY 8 2 2 Reception Without Error Shown is an example of transfer of a packet from PHY to MAC Tel 49 0 234 9351135 Fax 49 0 23...

Страница 25: ...11 0 15 0 22 0 29 between 0 10 mm and 0 25 mm from the lead tip b1 0 006 0 008 0 010 0 15 0 20 0 25 6 A1 is defined as the distance from the seating plane to the c 0 004 0 008 0 09 0 20 lowest point o...

Страница 26: ...eadquarters 1F No 2 Industry East Road IX Science based Industrial Park Hsinchu 300 Taiwan R O C Tel 886 3 5780211 Fax 886 3 5776047 WWW www realtek com tw Tel 49 0 234 9351135 Fax 49 0 234 9351137 E...

Отзывы: