Factory configured jumper settings
Figure 1-1 illustrates the general location of the onboard connectors and
jumpers. Table 1-1 will show some general jumper settings preset by the factory.
Refer to the following jumper specific information on usage of these jumpers.
Jumper name
Function
Setting
BASE
Base address
300h
IRQ1
Channel 1 IRQ
10
IRQ2
Channel 2 IRQ
11
SENSOR1
Sensor selection
Direct resolver
SENSOR2
Sensor selection
Direct resolver
Table 1-1
Factory preset jumpers
Fig. 1-1 Jumper and connector locations of the ERES104
Page 5
ERES104 Ver 1.2 (c) RTD Finland Oy 2000-2001