background image

2

REV 0 - 1411031020

L-A2-390

III

 

CONNECT TO VALVE

Select models require installation of remote receiver to burner system.

Connecting to an 01 Valve

Connecting to an 11/12 Valve

Switch Box Assembly

(Burner System)

Remote Receiver

(Remote System)

•  Locate two free wires on switch box assembly.

•  Connect remote wires.

•  Ensure all connections are fully attached.

A

B

Remove 

connectors

Connect 

remote wires

(wires to 

burner)

Switch

(Burner System)

Remote Receiver

(Remote System)

(burner 

valve)

Two methods exist (depending on model):

Toggle Switch (and select ON/OFF Switches)

•  Locate switch pre-installed to burner valve.

•  Remove and discard red connectors on switch (A).

•  Connect remote wires to now exposed terminals (B).

•  Ensure all connections are fully attached.

Important: DO NOT

 allow terminals to touch.

Valve

•  Connect remote wires to exposed terminals 

on valve.

•  Ensure all connections are fully attached.

OR

Valve

(Burner System)

Remote Receiver

(Remote System)

(burner 

valve)

Any ON/OFF or toggle switch (part of burner system) must be in off position when using remote system.

The ON/OFF switch must be in off position when using remote system.

Toggle switch shown