2
REV 0 - 1411031020
L-A2-390
III
CONNECT TO VALVE
Select models require installation of remote receiver to burner system.
Connecting to an 01 Valve
Connecting to an 11/12 Valve
Switch Box Assembly
(Burner System)
Remote Receiver
(Remote System)
• Locate two free wires on switch box assembly.
• Connect remote wires.
• Ensure all connections are fully attached.
A
B
Remove
connectors
Connect
remote wires
(wires to
burner)
Switch
(Burner System)
Remote Receiver
(Remote System)
(burner
valve)
Two methods exist (depending on model):
Toggle Switch (and select ON/OFF Switches)
• Locate switch pre-installed to burner valve.
• Remove and discard red connectors on switch (A).
• Connect remote wires to now exposed terminals (B).
• Ensure all connections are fully attached.
Important: DO NOT
allow terminals to touch.
Valve
• Connect remote wires to exposed terminals
on valve.
• Ensure all connections are fully attached.
OR
Valve
(Burner System)
Remote Receiver
(Remote System)
(burner
valve)
Any ON/OFF or toggle switch (part of burner system) must be in off position when using remote system.
The ON/OFF switch must be in off position when using remote system.
Toggle switch shown
(design and location