INTERFACING MAKE-UP AIR DAMPER INTO POWER FLUE OPERATION
(continued)
Operation
When the on/off switch is turned to the on position to operate the fire, the module will check that
the interlock safety switch of the make up air damper is in the open position, if it is, the fan will then
start up, the pressure switch located on the fan will then indicate to the module that the fan is
operating correctly, the module will then allow the gas to the fire and the fire will ignite.
After operating for 60 seconds the module will check that the make up air damper interlock safety
switch is in the closed position (which indicates that the damper is open), if the damper is open the
fire will continue to operate, if the damper is not open the fire will shut down.
MODELS
Ventilation Sq mm
Double Vision, Hot Box and all Heatseekers
18,000
Pure Vision, Simplicity, Elegance, Signature,
Hybrid 850, 1000 & 1500 Sizes
18,000
Pure Vision, Simplicity, Elegance, Signature,
Hybrid 1800 & 3300 Sizes
32,000