background image

3

Operating the Product

ow through the valve. You can shut off the water to the product by turning the tap on the valve clockwise until the 

ow stops.

4.  Turn on the internal ball valve. This is located under the sump. Remove the sump as described under ‘Cleaning’ in 

the Maintenance section

Please note: the water pressure is to be between 0.5Bar (50Kilopascals) and 8Bar (800Kilopascals)

If you do not feel con dent making this connection please consult a quali ed plumber, to ensure a safe and 

secure installation.

Electrical Connection

Plug the  re into a 10amp/240 volt outlet. Be sure to have access to the plug after installation to allow for disconnection. 

Ensure that the supply cable exits at the back of the  re, at the right or left hand corner to suit your supply socket location 

and is not trapped under the  re such that it might cause it to be damaged. If connecting multiple appliances into the 

same outlet be sure not to connect more that 5 appliances. If more appliances are required they must be connected into 

a separate circuit.

The  appliance  can  be  connected  to  the  xed  wiring  of  the  premises  through  a  suitable  connection  box  positioned 

adjacent to the appliance. This electrical installation must be carried out by a competent electrician and be in strict 

accordance with the current regulations for Electrical Equipment in Buildings. 

The electrician can remove the supplied plug by the following;

1.  Lift off the fuelbed and put switch ‘A’ into the off position (Fig 9).

2.  Ensure that the appliance is unplugged.

3.  Lift off the access cover by removing the retaining screw (Fig 15).

4.  Unscrew and remove the Live, Neutral and Earth wires.

5.  Unscrew the cable clamp (Fig 16 ‘A’) and remove the supply cord.

The electrician can then connect their wire from the appliance (by following the steps above in reverse) to the connection 

box ensuring that it incorporates a double pole isolating switch having a contact separation of at least 3mm. Brown - Live 

(L), Blue - Neutral (N) and Green/Yellow - Earth (E).

Assembling the LED Log Fuelbed

This product is equipped with a ‘metal fuelbed’. Before assembling the LED Log Fuelbed you have to lift off this metal 

fuelbed and place aside, (Fig.2). You can keep this for future use. Gently lift the LED Log Fuelbed out of its packaging. 

CAUTION: The fuelbed weighs 5kg. Be sure to only lift the Fuelbed by the two center logs (Fig.5). These are 

the strongest.

 Place the Fuelbed on top of the appliance, there are 4 plastic guides under the Fuelbed to help locate 

it, (Fig.6). The Fuelbed can be placed front to back or back to front, it is the customers preference how this is to be 

orientated. Once in place lift off the small loose log, this is held in place by magnets. Under this log there is a DC wire 

jack and a hole through the fuelbed. Connect this to the corresponding DC wire jack on the product through the holes in 

the Fuelbed, (Fig.7). The product is now assembled and is ready to be switched on.

There is also a loose non LED log packed with the Fuelbed. For the CAS500 this can be placed on top of the Fuelbed 

or stored away with the packaging. For the CAS1000 the loose log can be placed on the center join between the two 

Fuelbeds. 

Connecting the Receiver

Take your Receiver, 4button for CAS500 and 6button for CAS1000, and with the Fuelbed removed insert the 3.5mm 

jack into the socket at the back of the appliance (Fig.8). 

It is very important to make this connection for the product 

to function correctly.

 The Receiver has a cable length of 1.4m which will allow you position it anywhere around the 

product. If you prefer to hide it the Receiver can be placed inside the surround/wall. Please ensure that the Receiver is 

not enclosed in metal, concrete or any other dense material, this will affect the signal from the remote control.

This section describes how to activate your  re using either the manual controls or remote control.

MANUAL CONTROLS

The manual controls are located beneath the Fuelbed. (Fig.9)

CAS500

Mains Switch ‘A’:- Controls the electricity supply to the appliance.

Note: This switch must be in the ‘ON’ ( 

) position for the appliance to operate

Button panel ‘A’:- Controls the functioning of the appliance

• 

 is the on/standby button. Press it to turn on and off the  ame effect. Turning it on will be indicated by the main 

lights activating. Be careful not to look directly into the LED’s. These are very bright. Although the main lights operate 

immediately it will take a further 45 seconds before the  ame effect starts. 

• 

 is the Pairing button. This will pair your remote control to the receiver. See ‘Remote Control Operation’ for details

• 

 is the test mode button. This will be used by the manufacturer and the Service Engineer

Содержание OPTIMYST CAS1000

Страница 1: ...European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC Approval Number ESV160149 08 532...

Страница 2: ...ards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Some parts of this product can become very hot and...

Страница 3: ...nclosure above the product This will allow enough space above the product to allow the ames to form fully and not to be obstructed This product needs free ventilation from underneath to operate correc...

Страница 4: ...Log Fuelbed out of its packaging CAUTION The fuelbed weighs 5kg Be sure to only lift the Fuelbed by the two center logs Fig 5 These are the strongest Place the Fuelbed on top of the appliance there a...

Страница 5: ...inimum level is the increase ame button Press this to increase the height intensity of your ame You will hear an audible beep when you reach the maximum level is the reduce re crackling sound Press th...

Страница 6: ...the minimum level is the increase ame button for the right had side of the appliance Press this to increase the height intensity of your ame You will hear an audible beep when you reach the maximum l...

Страница 7: ...in the clip with one hand and with the other lift the nozzle our of the clip Repeat this for the right side Fig 11 The nozzle is now released lift this off and place aside Fig 12 6 Gently lift up the...

Страница 8: ...ould not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice PATENT PATENT APPLICATION Products within the Optimy...

Страница 9: ...Check that there are no leaks in the tubes check that the ball valve is in the on position Once the mains water has been re established turn back on the product as mentioned above Product will not op...

Страница 10: ...pplicable laws 2 Registration You must register to receive the bene t of this warranty by completing the warranty registration on our website www real ame com au or completing and mailing the attached...

Страница 11: ...sumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or r...

Страница 12: ...MODEL DIM A CAS500 508mm CAS1000 1017mm Fig 1 Fig 2 Fig 3a Fig 3b Fig 3c Fig 5 Fig 4...

Страница 13: ...C A B Fig 6 Fig 7 Fig 8b CAS500 CAS1000 Fig 8a Fig 10 Fig 11...

Страница 14: ...CAS1000 CAS500 Fig 9 Switch A Fig 12 Fig 13 Fig 14 L N E A Fig 15 Fig 16...

Страница 15: ...210cm2 210cm2 420cm2 420cm2 Fig 17 Fig 18...

Страница 16: ...elong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02...

Отзывы: