background image

5

II. Installation Materials Needed for your Safety

BAROMETRIC DAMPER

Reading

Stove

Company

recommends that a barometric
damper be installed in the
chimney

connector

pipe.

Maintaining the draft at a
controlled constant minimizes
the possibility of over-firing and
improves

the

combustion

efficiency.

The

Field

Model

R-C,

manufactured by Field Controls,
Kinston, North Carolina 28501,
is a preferred version because
it is easy to install and does not
require a draft gauge and tire
for set up.

The 6" Model R•C will fit in the
side leg of a standard single
wall black tee connector. [See
Figure 5:1]

The tee may be positioned anywhere within
the stove to chimney connection. It may be
installed in either vertical, horizontal or sloping
smoke pipe. However, it is critical at, accurate
calibration that the front edge of the side leg
is straight up and down, i.e.

perpendicular to

the floor.

[See Figures 5:2 and 6:1.]

INSTALLATION MATERIALS The Barometric

Damper

Содержание MAHANTONGO CS-45

Страница 1: ...THE MAHANTONGO ANTHRACITE COAL STOVE CS 45 OWNER S MANUAL READING STOVE COMPANY P O BOX 1200 200 MAHANTONGO STREET POTTSVILLE PA 17901 570 366 7788 www readingstove com...

Страница 2: ...ating Your Stove 8 Reduced Wall Clearances 9 Floor Protector 9 Venting system 9 Chimney Connector 9 Connection to a Masonry Chimney 10 Connection to a Masonry Fireplace 10 Connection to a Metal Prefab...

Страница 3: ...s than diameter will fall through the grate openings Note Pea size passes over and through nut size passes over and through 1 3 8 B THE CS 45 CUT AWAY VIEW 1 PRIMARY AIR 2 SECONDARY AIR 3 ASH COLLECTI...

Страница 4: ...ing thermal stresses and the entire assembly is air cooled to ensure that the glass is not heated beyond its limits Should one or both of the strips of glass ceramic break the stove s output is reduce...

Страница 5: ...ntained It is also important that the coal bed is of constant thickness A hole or thin area will allow combustion air to bypass the rest of the coal bed and eventually the fire will go out This stove...

Страница 6: ...28501 is a preferred version because it is easy to install and does not require a draft gauge and tire for set up The 6 Model R C will fit in the side leg of a standard single wall black tee connecto...

Страница 7: ...o the proper position and tighten The bracket is marked 2 4 6 and 8 which indicates the draft settings in one hundredths of inches of water column LOCATE THE WEIGHT IN ALIGNMENT BETWEEN THE 4 and 6 Th...

Страница 8: ...safe chimney installation Use only components manufactured for the chimney FLOOR PROTECTOR 1l4 Mineral board or equivalent Measurements 8 beyond the sides and back 18 beyond the front Total Dimensions...

Страница 9: ...in an open area to allow for necessary clearance Review Figures 8 1 and 8 2 for MINIMUM clearances MINIMUM CLEARANCES SHOWN IN FIGURES 8 1 and 8 2 ARE TO PREVENT WALLS AND CEILINGS FROM CATCHING FIRE...

Страница 10: ...nector must be 6 in diameter 24 gauge minimum carbon steel Do not use aluminum or galvanized steel They cannot properly withstand the extreme temperatures of a coal fire Do not use chimney connector p...

Страница 11: ...illustrated in this manual Local building authorities may be consulted or NFPA 211 may be used for additional methods of chimney connection Also listed prefabricated metal thimbles can be bought for...

Страница 12: ...ence through the ceiling and the roof See Figures 17 1 and 17 2 The other method is to install an exterior chimney that runs up the outside of the residence See Figures 18 1 and 18 2 The components il...

Страница 13: ...12...

Страница 14: ...13...

Страница 15: ...the stove the setting is high burn When the lever is pushed toward the back of the stove the setting is low burn A 1 The Stove Tool Each CS 45 comes with a multi function stove tool See Picture 19 2...

Страница 16: ...ommended that you wear gloves whenever working with a hot stove C 1 Push the primary air control towards the back of the stove low setting C 2 Using the stove tool slowly open the loading door CAUTION...

Страница 17: ...e Ash Tidy E 1 Description The ash tidy is designed to make ash removal easy safe and clean It is constructed with an inner scoop pan and the outer sealing container It is made of sheet steel to provi...

Страница 18: ...re the ash cleanout door E 3 f 2 Reset the primary air E 3 f CAREFULLY carry the ash tidy out of the house Remember it contains hot ashes and most likely some red hot coals Remember to store the ash t...

Страница 19: ...rts Reading Stove Company assumes no responsibility for any labor expenses for service removal or reinstallation If defective in material or workmanship and if removed by the owner within the warranty...

Страница 20: ...quential damages for breach of any written or implied warranty is disclaimed and excluded here from Some states do not allow the exclusion or limitations of incidental or consequential damages so the...

Страница 21: ...Zip UNIT INFORMATION Model Number CS 45 Mahantongo Purchase Date Serial No Important Notice This registration information must be on file for this warranty to be valid Please mail this information wit...