Thermostat Menu Mode 

 

The Thermostat has a menu of setup and information displays. 
Change to the Menu Mode by pressing and holding the FAN button for 5 seconds. 
The display will change to Menu Mode and you can scroll through the menu options with 
the Up/Down arrow buttons.  
 

Thermostat Main Screen 

 

 
 
 
 
 
 
 
 
 
 
 
 
Menu Mode Screen 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Menu Mode options 

 

SETUP

  User preference settings 

 

INFO

 

Displays thermostat version and setup info  

 

CLOCK

  Setting the thermostat time and day 

 

ZWAVE

  Z-Wave network install or remove  

 

SYSTEM

 Thermostat HVAC system settings 

 

 

 

Press and hold the 
FAN button for 5 
seconds to go to 
the Menu Mode 
screen    

Use the 

UP/DOWN 

buttons to select 

the desired menu 

item 

Press 

“Select” 

to go to the 

selected menu 

item screen 

Press 

“Done” to go back to the 

Thermostat Main Screen 

72H 80C 

 

2

 

Off

 

Auto 

MODE 

FAN 

SETUP 

 

 

Select

 

Done 

MODE 

FAN 

Menu item display 

firealarmresources.com

Содержание TBZ48A

Страница 1: ...you need to reinstall the old unit Read all instructions before starting installation Standard HVAC System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connection...

Страница 2: ...Do not install batteries if the thermostat is powered from 24VAC They are not required for backup Heating Cooling System HVAC Setup The thermostat must be setup for the correct system type and config...

Страница 3: ...rsions and Z Wave network information CLOCK set the time and day ZWAVE install uninstall from Z Wave network SYSTEM HVAC system setup Changing the HVAC default settings To change the HVAC system defau...

Страница 4: ...ype is automatically selected this selection is not used Changeover Valve Type CO For Heat Pump HVAC systems only The changeover or reversing valve is used to change from heating to cooling operation...

Страница 5: ...inimum separation between heating and cooling setpoints Note Attempts to lower the cooling setpoint below the heating setpoint will PUSH the heating setpoint down to maintain this separation The same...

Страница 6: ...cooling cycle can begin Provides compressor short cycle protection Heat Fan Purge H PURGE Range 0 90 Seconds Default 0 Runs the fan for this many seconds after the heat call ends A value of 0 is OFF...

Страница 7: ...or N Y 2 nd Stage Cool Y or N N H C Delta 3 15 deg 3 Heat Delta Stage 1 On 1 6 1 Heat Delta Stage 1 Off 0 5 0 Heat Delta Stage 2 On 2 7 2 Heat Delta Stage 2 Off 0 6 0 Heat Delta Stage 3 On 3 8 3 Heat...

Страница 8: ...call with heat call 3 CO Not used for standard systems Ignore this setting Go to ADVANCED SYSTEMS SETTINGS to set the following 4 AUX HT Not used for standard systems Ignore this setting 5 2ND HT Ena...

Страница 9: ...O or B connect the wire to the thermostats W2 O terminal The setting of the CO Type will set the correct system operation For changeover with cooling systems Orange wire set to C cool most common and...

Страница 10: ...g displayed System is ON and cooling blinking System is ON and heating Minimum Run Time MRT delay is active blinking System is ON and cooling Minimum Run Time MRT delay is active Temperature Setting W...

Страница 11: ...he setpoints Special Heat Pump Mode Emergency Heat Heat E An additional system mode Heat E for Emergency Heat will be displayed if the HVAC system type is set to Heat Pump If there is a compressor fai...

Страница 12: ...nt It maintains a 3 degree separation between the heating and cooling setpoint The same is true for raising the heating setpoint above the cooling setpoint Again the thermostat will push the cooling s...

Страница 13: ...change the Fan mode Fan Modes Auto Fan automatically operated by the HVAC system normal setting On Manual Fan mode Fan stays on until mode is changed back to Auto independent of the heating or coolin...

Страница 14: ...ode options SETUP User preference settings INFO Displays thermostat version and setup info CLOCK Setting the thermostat time and day ZWAVE Z Wave network install or remove SYSTEM Thermostat HVAC syste...

Страница 15: ...stat firmware version ZWAVE Z Wave firmware version NODE ID Z Wave Node ID HOME ID Z Wave Home ID SYSTYPE STANDARD standard HVAC system HP Heat Pump HVAC system If HVAC type Standard FAN TYPE GAS ELEC...

Страница 16: ...off immediately The MRT can be adjusted in the Installer Settings menu of the thermostat Note The MRT status is shown in the thermostat Status display Minimum Off Time MOT The thermostat has a Minimu...

Страница 17: ...re installing the TBZ48A into a Z Wave Network check that is not already installed in a network by viewing the Home and Zone ID s located in the INFO screen An un installed TBZ48A will show a Node ID...

Страница 18: ...controller be installed first proceeding out in consecutive rings from the controller Exclusion Removing the TBZ48A from a network 1 Set your primary controller to Uninstall or Remove mode to remove t...

Страница 19: ...is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect...

Отзывы: