SETUP Menu  

User preference settings. 

 

FAHRENHEIT OR CELSIUS.  

Select the temperature display mode.  

 

BACKLIGHT TIMEOUT. 

 Sets the time from last button press that the backlight will turn off.  

Range:10-30 seconds. Note: long backlight timeouts will reduce battery life. 

 

If the thermostat is powered from 24VAC, the backlight timeout can be set to “0” which will 

keep the backlight on continuously. 

 

SENSOR CALIBRATION  

Change the temperature calibration by +/- 7 degrees. 

Use the Up/Dn arrow buttons to change to the desired display temperature. 

 

 

SYSTEM Menu  

 

SYSTEM TYPE.  

Select the system type, 

STANDARD 

or

 HEAT PUMP

 

 

FAN TYPE 

(Standard systems only). 

  

Select fan type:  

GAS 

(typical default setting) or 

ELECTRIC

 

 

CHANGE OVER TYPE 

(Heat Pump systems only). 

  

Select the Changeover type: 

Changeover WITH COOL (typical default setting) 

Changeover WITH HEAT 

 

See Installation Guide for more information on System setup and the Advanced Systems 

Menu 

 

Z-WAVE Menu 

 

This menu item allows the thermostat to be enrolled to the ADT Pulse

®

 Network. Follow the 

instructions shown in the Z-Wave® Operation section (page 19) to enroll the Thermostat 

onto the ADT Pulse

®

 system. 

 

CLOCK Menu  

 

Set the time and day of the week. 

 

Press select to set the DAY.  The current day of the week setting will be displayed.   

Press the UP/DN arrows to change the day of the week desired. 

 

Press select to set the TIME.  The current time will be displayed.   

Press the UP/DN arrows to change the time. 

 

DCN: 140-02121-06 

Page 17 

 

Содержание TBZ48

Страница 1: ...line batteries and replace in complete sets 2 or 4 at a time with new batteries Z Wave Operation when Battery Powered Important Note If the thermostat is installed on a Z Wave network while it is batt...

Страница 2: ...nd RH Connections Typical installations will have a common heating and cooling system 24VAC transformer in the HVAC system For these systems there is only one R wire and it can connect to either the R...

Страница 3: ...sh all the excess wiring back into the wall RC RH JUMPER Cut jumper to allow connection of separate RC and RH wires Y2 Y1 G RC C RH W1 W2 O Y G R C Connect the wires as marked from the HVAC system to...

Страница 4: ...e base Install the batteries if the thermostat is not 24VAC powered no common C wire Open the front door and install 2 or 4 AA alkaline batteries Turn on the power at the HVAC system or breaker panel...

Страница 5: ...heat fan on with heat call For Two Stage Heat Cool Systems Go to ADVANCED SYSTEMS SETTINGS menu From the Setup menu screen press and hold the Fan and Down arrow buttons for 5 seconds Use the Down arr...

Страница 6: ...ire to the thermostats W2 O terminal For Two Stage Heat Cool Systems Go to ADVANCED SYSTEMS SETTINGS menu From the Setup menu screen press and hold the Fan and Down arrow buttons for 5 seconds Use the...

Страница 7: ...Control Screen To change the thermostats HVAC system settings select the Menu Screen and then select the SYSTEM menu Follow instructions below to access the SYSTEM menu Note To conserve battery life t...

Страница 8: ...h Cooling or with Heating When SYSTEM is selected in the Menu options the following setup options will be displayed in the text line Use the UP Down arrow buttons to scroll to the desired setting Pres...

Страница 9: ...ting comes on when cooling is expected or vice versa change the Change Over Type to the opposite setting Advanced System Settings Menu The Advanced System Settings Menu provides for addition system se...

Страница 10: ...15C Sets the minimum cooling setpoint value Will not ramp or accept setpoints lower than this minimum Heat Blower Off Delay Range 0 90 seconds Default 0 off Sets the system blower delay off time afte...

Страница 11: ...a from setpoint that stage 1 cooling stops Stage 1 turns off at setpoint Delta Stage 1 Cooling Stage 2 On Threshold Range 2 to 8 degrees Default 2 Sets the delta from setpoint that stage 2 cooling sta...

Страница 12: ...em is ON and cooling blinking System is ON and heating Minimum Run Time MRT delay is active blinking System is ON and cooling Minimum Run Time MRT delay is active Temperature Setting Warmer Cooler Fan...

Страница 13: ...mp Mode Emergency Heat Heat E An additional system mode Heat E for Emergency Heat will be displayed if the HVAC System Type is set to Heat Pump If there is a compressor failure with the Heat Pump syst...

Страница 14: ...ee separation is maintained between the heating and cooling setpoints The same is true for raising the heating setpoint above the cooling setpoint The thermostat will push the cooling setpoint up to m...

Страница 15: ...n mode Fan Modes Auto Fan automatically operated by the HVAC system normal setting On Manual Fan mode Fan stays on until mode is changed back to Auto independent of the heating or cooling system opera...

Страница 16: ...ptions SETUP User preference settings SYSTEM Thermostat HVAC system settings ZWAVE Z Wave network install or remove CLOCK Setting the thermostat time and day INFO Displays thermostat version and setup...

Страница 17: ...s only Select fan type GAS typical default setting or ELECTRIC CHANGE OVER TYPE Heat Pump systems only Select the Changeover type Changeover WITH COOL typical default setting Changeover WITH HEAT See...

Страница 18: ...tpoint room temperature or you change the setpoint to a temperature that would satisfy the call until the MRT expires Changing the Mode to OFF will cancel the MRT and the system will turn off immediat...

Страница 19: ...network while powered by 24VAC it will be enrolled as an always listening device and can act as a router node in the Z Wave network Caution Once installed in a Z Wave network if you change how the the...

Страница 20: ...ick the Manage Devices button 2 In the Manage Devices Assistant click Lights Thermostats more 3 Select the RCS Battery Powered Thermostat Model TBZ48 from the drop down list then click the Continue bu...

Страница 21: ...status line Press Select to install in the network Wait until SUCCESS or FAILED is shown on the status display 8 Press Done on the Thermostat to exit the ZWAVE screen 9 Press Done on the Thermostat ag...

Страница 22: ...en is displayed 2 Press the UP arrow button to scroll to the ZWAVE menu 3 Press Select to select the ZWAVE screen 4 The display will show REMOVE in the text line 5 Press Select to perform the Reset De...

Страница 23: ...to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment...

Отзывы: