Rcom MX-BL700R Скачать руководство пользователя страница 9

DIGITAL INCUBATOR

9

NOTICE

If float switch doesn’t work properly, the water may 

overflow.

Please check end of floate switch [Fig-2] in humidity tank

[Fig-1] whether it moves to up and down by using your

fingers.

When the products are stored long time, the float switch

may not work smoothly.

After using Brooder, if you don’t use Brooder for about one

month, please check end of floate switch whether it moves

to up and down by using your fingers.

After checking float switch, please assemble a filter like

the reverse of disassemble.

[Fig-2]

Humidity

tank

[Fig-1]

Up and down 

Make sure that 

the moving

Put UV lamp into socket on the left, turn left to lock.

[ How to UV lamp assemble ] 

2. Brooding

(2) Instructions for Installation

North America Sales & Service www.RcomCo.com

Rcom Reptile Brooder User Manual

Содержание MX-BL700R

Страница 1: ...Love of life begins with Rcom USER S MANUAL Ver 1 1 DIGITAL REPTILE BROODER MX BS700R MX BL700R North America Sales Service www RcomCo com Rcom Reptile Brooder User Manual...

Страница 2: ...North America Sales Service www RcomCo com Rcom Reptile Brooder User Manual...

Страница 3: ...tion Brooding Product Information Function Settings How to Clean How to use Rcom REPTILE BROODER The manufacturer or the vendor does not take responsibility for any loss of animal life or property dam...

Страница 4: ...ire If the machine sounds strange or emits smoke contact your service center Risk of electric shock or fire Do not use for high priced animals Risk of knocking the incubator or accidental interference...

Страница 5: ...ing opening Water conection Air filter Operation part Tray Indoor Outlet UV LAMP DIGITAL INCUBATOR 5 Identification of Parts Powerconnection back This is where you connect the power cable Silicon hose...

Страница 6: ...lay Humidity activation lamp Temperature down Humidity Down Press ON OFF button at the same time to set up UV lamp time Conversion between Celsius Fahrenheit UV lamp ON OFF Press ON OFF button at the...

Страница 7: ...utlet time Press and buttons simultaneously to be shown LEd on display then starts setting mode Press button in once 1 hour unit of time is going up Press button to going down the time in unit of 1 ho...

Страница 8: ...de environment condition of where the product was installed Temperature 20 25 68 77 Humidity 40 60 Instructions for Installation Remove the vinyl cover on the front of the sight class then take out th...

Страница 9: ...ing Brooder if you don t use Brooder for about one month please check end of floate switch whether it moves to up and down by using your fingers After checking float switch please assemble a filter li...

Страница 10: ...utors will charge for your after service The equipment operates when the power cord is connected to the back of the main body as in Fig B and the power plug is connected to the power outlet Do not pla...

Страница 11: ...face To prevent this the equipment should be turned off after the internal humidity is eliminated by emptying the humidifying water container and running the equipment for about one hour before turnin...

Страница 12: ...ting the temperature to 20 or higher by pushing the TEMP button while the SET button is pushed pushing the TEMP button once will stop the heating function and H OFF will appear on the display unit The...

Страница 13: ...Current temp and A OFF will show on display in turn while you set OFF to Ventilation fan function please set off to heating in case you do not want to activate the heating Heating unit lifespan will b...

Страница 14: ...own LEd on display then starts setting mode Press button in once 1 hour unit of time is going up Press button to going down the time in unit of 1 hour If you press SET button to save the setting The a...

Страница 15: ...n the display unit How to turn ON OFF Sound How to change Cels Fahr How to change outlet time Press ON and OFF buttons simultaneously to be shown Out on display then starts setting mode Press ON butto...

Страница 16: ...eft at the same time and using your fingers or a screwdriver then pulling in the direction of Picture and pulling to the front of direction in Picture At this point do NOT completely remove the silico...

Страница 17: ...ed Clean once every week Humidifier malfunction caused by debris scale collected around the humidifying container from poor cleaning is considered to be the customer s fault and repair will be charged...

Страница 18: ...3 Broken or problem caused by Trying Reptile hatching in incubator Please don t try Reptile hatching in incubator Please use Hatcher during Reptile hatching 4 Broken or problem caused by Wrong control...

Страница 19: ...Rcom Reptile Brooder User Manual...

Страница 20: ...easy and convenient use It can be changed without notice for improvement in performance design treatment and software etc MANUFACTURER OFFICE 218 Sangdong ro Sangdong myeon Gimhae si Gyeongsangnam do...

Отзывы: