1

.

  

Mount the strike into the frame without the faceplate. Tighten  

 

the  mounting screws just enough to hold the strike in place;  

 

you may need to slide it up-down for adjustment.

Adjust Deadbolt Keeper:                                                                                                                       

First, extend the deadbolt and move the door so that deadbolt 

touches the keeper.                

Mark  deadbolt  limit  lines  on  strike  keeper.                                                                                                   

Then, open the door and retract the deadbolt. Adjust the  

deadbolt keeper position so that it aligns with deadbolt limit 

lines marked on keeper. Move the strike up-down if needed.

Adjust Deadlatch Ramp:

First, move the door towards the strike so that the deadlatch

touches the keeper.                   

Mark deadlatch limit lines on keeper.                                                             

Then, open the door. Adjust the deadlatch ramp so that it  

aligns with deadlatch limit lines marked on keeper.

© 2016 RUTHERFORD CONTROLS INT’L | A DORMA GROUP COMPANY

WWW.RUTHERFORDCONTROLS.COM • PHONE: 1.800.265.6630 • FAX: 1.800.482.9795 • E-MAIL: [email protected]

Содержание F2164

Страница 1: ...on diode is required for access control observe proper polarity Latch Monitor Wires Black Common C Blue Normally Closed NC Orange Normally Open NO Red Black Red Black 24VDC Terminal 12VDC 12 24VAC Terminal NO NC C Latch Monitor Optional LM Wiring the 2 Series Electric Strike Warning The fire and security ratings shown on the strike labels no longer apply with the use of this faceplate The F2164 fa...

Страница 2: ... strike keeper Then open the door and retract the deadbolt Adjust the deadbolt keeper position so that it aligns with deadbolt limit lines marked on keeper Move the strike up down if needed Adjust Deadlatch Ramp First move the door towards the strike so that the deadlatch touches the keeper Mark deadlatch limit lines on keeper Then open the door Adjust the deadlatch ramp so that it aligns with dea...

Страница 3: ...sing so that it is between the latch limit lines marked on keeper 2 Mark strike position on the frame 3 Peel the adhesive backing from tape on the back side of the appropriate faceplate Remove the strike mounting screws Hold the strike in position as marked on frame Carefully position the faceplate onto the strike and secure to the frame 2016 RUTHERFORD CONTROLS INT L A DORMA GROUP COMPANY WWW RUT...

Страница 4: ...olt keeper with deadbolt plug NOTE Deadlatch Ramp also acts as a Keeper stop so don t forget to insert it for centerline cylindrical lock applications Deadbolt Plug Cylindrical Horizontal Adjustment If there is play in the door when closed the keeper shims may be used to minimize play Keeper Sliding Shim 2016 RUTHERFORD CONTROLS INT L A DORMA GROUP COMPANY WWW RUTHERFORDCONTROLS COM PHONE 1 800 26...

Отзывы: