![RCI F2164 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/rci/f2164/f2164_installation_1424026002.webp)
2
Fail Locked F2164 (Fire-Rated) & Fail Unlocked 2364 Installation Instructions (Continued)
1
.
Mount the strike into the frame without the faceplate. Tighten
the mounting screws just enough to hold the strike in place;
you may need to slide it up-down for adjustment.
Adjust Deadbolt Keeper:
First, extend the deadbolt and move the door so that deadbolt
touches the keeper.
Mark deadbolt limit lines on strike keeper.
Then, open the door and retract the deadbolt. Adjust the
deadbolt keeper position so that it aligns with deadbolt limit
lines marked on keeper. Move the strike up-down if needed.
Adjust Deadlatch Ramp:
First, move the door towards the strike so that the deadlatch
touches the keeper.
Mark deadlatch limit lines on keeper.
Then, open the door. Adjust the deadlatch ramp so that it
aligns with deadlatch limit lines marked on keeper.
© 2016 RUTHERFORD CONTROLS INT’L | A DORMA GROUP COMPANY
WWW.RUTHERFORDCONTROLS.COM • PHONE: 1.800.265.6630 • FAX: 1.800.482.9795 • E-MAIL: [email protected]