IMPORTANT

Before connecting and using this product, please read this instruction manual carefully and 
keep it on hand for future reference.
The manual is to be considered an integral part of this product and must accompany it when 
it changes ownership as a reference for correct installation and use as well as for the safety 
precautions.

RCF S.p.A.

 will not assume any responsibility for the incorrect installation and / or use of this 

product.

WARNING: 

To prevent the risk of fire or electric shock, never expose this product to rain or 

humidity.

SAFETY PRECAUTIONS
1. 

All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2.1 PRIMARY POWER SUPPLY FROM MAINS

 

-

The mains voltage is sufficiently high to involve a risk of electrocution: never install or 
connect this product when its power cord is plugged in.

 

-

Before powering up, make sure that all the connections have been made correctly and the 
voltage of your mains corresponds to the voltage shown on the rating plate on the unit, if 
not, please contact your RCF dealer.

 

-

The metallic parts of the unit are earthed by means of the power cord.

 

-

An apparatus with CLASS I construction shall be connected to a mains socket outlet with a 
protective earthing connection.

 

-

Protect the power cord from damage. Make sure it is positioned in a way that it cannot be 
stepped on or crushed by objects.

 

-

To prevent the risk of electric shock, never open this product: there are no parts inside that 
the user needs to access.

2.2 SECONDARY (/ EMERGENCY) POWER SUPPLY THROUGH BATTERIES

 - WARNING: use external DC power source with 15A current rating protection facility.

 

-

The apparatus operating voltage is 24 V dc (therefore, it is necessary to connect in series 
several batteries having a lower nominal voltage, example: 2 x 12 V).

 

-

Always use rechargeable batteries, which need to be chosen according to the maximum 
possible load.

 

-

Verify the polarity of batteries is correct.

 

-

Do NOT short-circuit batteries (i.e. connecting the 2 opposite poles together with metallic 
wires).

 

-

Throw empty batteries away according to your country laws about ecology and environment 
protection.

3.

 Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit. This apparatus shall not be exposed to dripping or splashing. No objects filled with 
liquid, such as vases, shall be placed on this apparatus. No naked sources (such as lighted 
candles) should be placed on this apparatus.

4. 

Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual. 
Contact your authorized service centre or qualified personnel should any of the following occur:

 

-

The product does not function (or functions in an anomalous way).

 

-

The power cord has been damaged.

 

-

Objects or liquids have got in the unit.

 

-

The product has been subject to a heavy impact.

5.

 If this product is not used for a long period, disconnect the power cord (and or batteries).

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately and 

disconnect the power cord (and / or batteries).

IMPORTANT

WARNING

SAFETY PRECAUTIONS

WARNING

Содержание UP 1121

Страница 1: ...OWNER MANUAL MANUALE D USO UP 1121 AMPLIFICATORE UNITÀ DI POTENZA POWER AMPLIFIER ...

Страница 2: ......

Страница 3: ...ACK CABINETS FRONT PANEL REAR PANEL LOUDSPEAKER CONNECTION SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE INSTALLAZIONE NEI RACK DA 19 PANNELLO FRONTALE PANNELLO POSTERIORE COLLEGAMENTO DEI DIFFUSORI ACUSTICI SPECIFICATIONS 4 6 6 6 7 8 9 10 12 12 12 13 14 15 ...

Страница 4: ... there are no parts inside that the user needs to access 2 2 SECONDARY EMERGENCY POWER SUPPLY THROUGH BATTERIES WARNING use external DC power source with 15A current rating protection facility The apparatus operating voltage is 24 V dc therefore it is necessary to connect in series several batteries having a lower nominal voltage example 2 x 12 V Always use rechargeable batteries which need to be ...

Страница 5: ...ion Sudden stops excessive pushing force and uneven floors may cause the assembly to overturn 11 Mechanical and electrical factors need to be considered when installing a professional audio system in addition to those which are strictly acoustic such as sound pressure angles of coverage frequency response etc 12 Hearing loss Exposure to high sound levels can cause permanent hearing loss The acoust...

Страница 6: ...s indicate power on and the audio signal level Fix the amplifier with the included rack ears to the 19 rack front Add RCF P AER 1V front ventilation panels at least one between each amplifier pair INSTALLATION INTO 19 RACK CABINETS FRONT PANEL 1 BASS tone control use a screwdriver to adjust centre position flat response 2TREBLE tone control use a screwdriver to adjust centre position flat response...

Страница 7: ...ins supply is unavailable Make sure the connection polarity is correct and use a cable having wires with a suitable section at least 2 5 mm WARNING use external DC power source with 15A current rating protection facility P Mains connector with fuse Before connecting the power cord verify the mains voltage either 230 V or 115 V corresponds to the amplifier operating voltage set by the respective se...

Страница 8: ...ce equal to 4 Ω allows the amplifier maximum power delivery A higher impedance leads to a reduction of the power delivered by the amplifier e g 8 Ω approx power 16 Ω approx power An impedance lower than 4 Ω overloads the amplifier Loudspeaker models shall be chosen by considering the max power that the amplifier can deliver Loudspeaker line should be as short as possible long cables may need large...

Страница 9: ...IVITY 1 V 2 dBu INPUT IMPEDANCE 10 kΩ balanced AMPLIFIER OUTPUT TO LOUDSPEAKERS 100 V 83 Ω 70 V 42 Ω 4 Ω LEDS Blue power on green 20 dB signal orange 9 dB signal red 0 dB signal peak POWER SUPPLY 115 V 230 V 24 V dc MAX CONSUMPTION 350 W OPERATING TEMPERATURE 10 45 C 14 113 F DIMENSIONS W H D 431 mm 88 mm 385 mm 19 rack 2 units NET WEIGHT 12 kg ...

Страница 10: ...rfetta integrità Per evitare il rischio di shock elettrici non aprire mai l apparecchio all interno non vi sono parti che possono essere utilizzate dall utente 2 2 ALIMENTAZIONE SECONDARIA D EMERGENZA TRAMITE BATTERIE ATTENZIONE l alimentazione in c c 24 V deve essere protetta da sovraccarico per un intensità di corrente superiore a 15 A L apparecchio funziona con tensione 24 V in corrente continu...

Страница 11: ...amento dell assieme 11 Vi sono numerosi fattori meccanici ed elettrici da considerare quando si installa un sistema audio professionale oltre a quelli prettamente acustici come la pressione sonora gli angoli di copertura la risposta in frequenza ecc 12 Perdita dell udito L esposizione ad elevati livelli sonori può provocare la perdita permanente dell udito Il livello di pressione acustica pericolo...

Страница 12: ... ogni amplificatore sul lato frontale del rack da 19 tramite le alette laterali incluse Inserire un pannello d aerazione RCF P AER 1V tra un amplificatore e l altro INSTALLAZIONE NEI RACK DA 19 PANNELLO FRONTALE 1 Controllo comune dei toni bassi BASS utilizzare un cacciavite per effettuare la regolazione posizione centrale nessun intervento 2 Controllo comune dei toni alti TREBLE utilizzare un cac...

Страница 13: ... polarità del collegamento sia corretta ed utilizzare un cavo con conduttori di sezione adeguata almeno 2 5 mm ATTENZIONE l alimentazione in c c 24 V deve essere protetta da sovraccarico per un intensità di corrente superiore a 15 A P Connettore con fusibile per il collegamento del cavo d alimentazione principale da rete Prima di effettuare il collegamento verificare che la tensione di rete corris...

Страница 14: ...guale a 4 Ω permette la massima erogazione di potenza dell amplificatore un impedenza superiore comporta una riduzione della potenza erogata es 8 Ω circa potenza 16 Ω circa potenza un impedenza inferiore a 4 Ω sovraccarica l amplificatore La somma delle potenze dei diffusori deve essere adeguata alla potenza massima erogabile dall amplificatore La lunghezza delle linee diffusori deve essere ridott...

Страница 15: ...TÀ INGRESSO AUDIO 1 V 2 dBu IMPEDENZA INGRESSO AUDIO 10 kΩ bilanciato USCITA AMPLIFICATA PER DIFFUSORI 100 V 83 Ω 70 V 42 Ω 4 Ω LED blu accensione verde segnale 20 dB arancio segnale 9 dB rosso segnale 0 dB picco ALIMENTAZIONE 115 V 230 V 24 V dc CONSUMO MASSIMO 350 W TEMPERATURA DI FUNZIONAMENTO 10 45 C DIMENSIONI L H P 431 mm 88 mm 385 mm 2 unità rack 19 PESO NETTO 12 kg ...

Страница 16: ... 1234 Int 44 870 626 3142 e mail info rcfaudio co uk RCF France tel 33 1 49 01 02 31 e mail france rcf it RCF Germany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info rcfaudio es RCF Belgium tel 32 0 3 3268104 e mail belgium rcf it RCF USA Inc tel 1 603 926 4604 e mail info rcf usa com ...

Отзывы: