The system is equipped with an RDNet connection on board. Using an RDNet controller unit it is possible
to:
-
receive status information from the system ( amplifiers status, signal levels, system settings,…)
-
send commands to the system (mute, solo, change sensitivity, change setting, set user eq, … )
See the RDNet user manual for details.
RDNet BY-PASS SWITCH
When the RDNet is present and the RDNet LINK LED is green the controller takes control over the module
independently of the BY-PASS SWITCH position
When the
RDNet is not present
, the BY-PASS switch act as follow:
-
BY-PASS SWITCH pressed
(LED ON):
The system bypass the input board and reads the
RDNet user settings (
last configuration saved
).
-
BY-PASS SWITCH released
(LED OFF): The system
reads the input board
and bypass the user
setting eventually loaded ion the speaker (last configuration eventually saved).
TTS26-A DEFAULT CONFIGURATION
The TTS26-A
factory default configuration
(the configuration that the system reads if the BY-PASS
switch is pressed) is the following:
Sensitivity
+4 dBu
High pass
30 Hz
Low pass
150 Hz
Cardioid
OFF
Delay
0
Bypass
OFF
User filters
ALL FLAT
If the user set with RDNet a new configuration, the new configuration will be recalled when the BY-PASS switch is
pressed.
BY-PASS SWITCH
RDNet
BY-PASS LED
FUNCTION
ON
ON
ON
Reads RDNet settings
OFF
ON
OFF
Reads RDNet settings
ON
OFF
ON
Reads last saved used configuration
OFF
OFF
OFF
Reads input panel