background image

3

ENGLISH

1.

 

All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2. 

Power supply from mains

a.  The mains voltage is sufficiently high to involve a risk of electrocution; install and 

connect this product before plugging it in.

b.  Before powering up, make sure that all the connections have been made correctly and 

the voltage of your mains corresponds to the voltage shown on the rating plate on the 
unit, if not, please contact your RCF dealer.

c.  The metallic parts of the unit are earthed through the power cable. An apparatus with 

CLASS I construction shall be connected to a mains socket outlet with a protective 
earthing connection.

d.  Protect the power cable from damage; make sure it is positioned in a way that it 

cannot be stepped on or crushed by objects.

e.  To prevent the risk of electric shock, never open this product: there are no parts inside 

that the user needs to access.

3.

 Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit.
This apparatus shall not be exposed to dripping or splashing. No objects filled with liquid, 
such as vases, shall be placed on this apparatus. No naked sources (such as lighted candles) 
should be placed on this apparatus.

4. 

Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual.
Contact your authorized service centre or qualified personnel should any of the following 
occur:

the product does not function (or functions in an anomalous way).

- The power cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.

5.

 If this product is not used for a long period, disconnect the power cable.

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately 

and disconnect the power cable.

7.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang 
this product by using elements that are unsuitable or not specific for this purpose. Also 
check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.), and the components used for attachment (screw anchors, screws, brackets 
not supplied by RCF etc.), which must guarantee the security of the system / installation 
over time, also considering, for example, the mechanical vibrations normally generated by 
transducers.
To prevent the risk of falling equipment, do not stack multiple units of this product unless 
this possibility is specified in the user manual.

8. RCF S.p.A. strongly recommends this product is only installed by professional 
qualified installers (or specialised firms) who can ensure correct installation 
and certify it according to the regulations in force.
The entire audio system must comply with the current standards and regulations 
regarding electrical systems.

9.

 Supports and trolleys. 

The equipment should be only used on trolleys or supports, where necessary, that are 
recommended by the manufacturer. The equipment / support / trolley assembly must be 

SAFETY

PRECAUTIONS

IMPORTANT

Содержание SUB 8003-AS II

Страница 1: ...OWNER MANUAL SUB 8003 AS II SUB 905 AS II ACTIVE SUBWOOFERS...

Страница 2: ...2 ENGLISH ENGLISH ITALIANO LANGUAGE 4 10...

Страница 3: ...ur the product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this prod...

Страница 4: ...T NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Lou...

Страница 5: ...ransportation but also assist in the heat dissipation The new loudspeaker design looks aggressive whilst retaining perfect ergonomics and is the result of extensive combined functional and acoustic re...

Страница 6: ...There are two possible high pass choices 30 Hz or 40 Hz and four low pass choices 60 Hz 80 Hz 100 Hz 125 Hz for eight preset combinations Cardioid presets are available for all 30 Hz high pass preset...

Страница 7: ...t LED will light up Now rotating the encoder clockwise it will be possible to select a preset EXTENDED LOW PRESETS more extended and linear frequency response L1 30 Hz 60 Hz L2 30 Hz 80 Hz L3 30 Hz 10...

Страница 8: ...reset The 2 front modules shall have 1 5 dB gain less than the rear module HOT GND BAL XLR COLD CONNECTIONS CARDIOID SET UP The fuse settings replacement shall be as follow FUSE VALUE T 6 30 A H 250 V...

Страница 9: ...prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecch...

Страница 10: ...re che i monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0 dB usare solo cav...

Страница 11: ...durante il trasporto e gli urti ma assiste la dissipazione termica Il nuovo design della Sub Series risulta aggressivo pur mantenendo caratteristiche ergonomiche familiari ed il risultato di estese r...

Страница 12: ...ssibili due scelte di passa alto 30 Hz e 40 Hz e quattro scelte di passa basso 60 Hz 80 Hz 100 Hz 125 Hz Sono inoltre disponibili preset per configurazione cardioide nel caso di passa alto configurato...

Страница 13: ...ore Il ritardo espresso in metri Il ritardo in passi da 0 1 metri per i primi 10 metri e in passi da un metro per i successivi Il massimo ritardo di 20 metri Premendo una terza volta l encoder posteri...

Страница 14: ...nte sar un mixer importante anche che il mixer sia gi acceso al momento in cui viene acceso il diffusore a lui collegato Queste due precauzioni vi eviteranno innanzitutto di accendere i diffusori in p...

Страница 15: ...35 dB 18 4 0 v c Stereo XLR Stereo XLR 0 dBu 99 dBu Selectable thermal rms dynamic limiter Gain EQ xover delay cardioid 2200 W Peak 2200 W Peak convection Powercon in out 694 mm 27 32 523 mm 20 59 700...

Страница 16: ...www rcf it RCF S p A Via Raffaello Sanzio 13 42124 Reggio Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it 10307484 RevA...

Отзывы: