5.3 System parameters array P 6215
* 96 dB SPL 400Hz-4 kHz with no atmospheric effects; rounded to the nearest 1 meter
NOTE: The distances indicated in the table are referred to the frequency range 400Hz-4 kHz.
Array
system
Inclination
angle (
α
)
Distance MAX
*
Coverage Angle - 6 dB
(H - V)
Accessory to
be used
Suggested
Amplifier
400 Hz - 4 Khz
500 Hz
1 kHz
2 kHz
4 kHz
3 - A
3 - B
0 °
0 °
55 m
110°x60°
70°x35°
80°x60°
60°x70°
AC P15A-BR
HPS 2500
4 - A
4 - B
0 °
30 °
50 m
110°x60°
70°x40°
80°x70°
60°x90°
AC P15A-BR
HPS 2500
5 - A
5 - B
5 - C
0 °
10 °
10 °
55 m
110°x40°
70°x30°
80°x75°
60°x35°
2 X
AC P15A-BR
2 X
HPS 2500
6 - A
6 - B
6 - C
0 °
0 °
30 °
60 m
110°x45°
70°x50°
80°x85°
60°x80°
2 X
AC P15A-BR
2 X
HPS 2500
7 - A
7 - B
7 - C
7 - D
0 °
0 °
0 °
0 °
80 m
110°x30°
70°x20°
80°x25°
60°x40°
2 X
AC P15A-BR
2 X
HPS 2500
8 - A
8 - B
8 - C
8 - D
0 °
0 °
10 °
30 °
55 m
110°x40°
70°x55°
80°x25°
60°x35°
2 X
AC P15A-BR
2 X
HPS 2500
9 - A
9 - B
9 - C
9 - D
0 °
10 °
10 °
10 °
65 m
110°x40°
70°x40°
80°x35°
60°x40°
2 X
AC P15A-BR
2 X
HPS 2500
10 - A
10 - B
10 - C
10 - D
0 °
20 °
20 °
30 °
45 m
110°x35°
70°x35°
80°x25°
60°x40°
2 X
AC P15A-BR
2 X
HPS 2500
A
B
C
D
α
A
α
B
α
C
α
D
Содержание P Series