11
ENGLISH
FRONT PANEL LEDS
The front panel LEDs indicate the current unit status:
After fixing faults, all fault indications will be reset.
Anyhow, the fault is listed to the system Error Log.
N
ote
:
the
Mt 7308
coNNectioN
should
be
carried
out
carefully
,
siNce
possible
iNcorrect
settiNgs
caN
daMage
exterNal
aMplifiers
(
aNd
also
loudspeakers
).
Connect the MU 7100EN ‘Local Bus’ to the MT 7308
DATA
3
input through a CAT-
5 cable with RJ45 plugs.
The
LINK
4
parallel output can be used to link other devices to the ‘Local Bus’.
External amplifier audio inputs can be linked to the MU 7100EN loudspeaker outputs
through dedicated attenuators that reduce signal levels to 0 dBu (see the figure).
If necessary, each level can be adjusted by the respective trimmer.
The factory attenuation is set for a 6 dBu amplifier input sensitivity.
CONNECTION
‘ON’
green LED
‘FAULT’
red LED
dark
dark
Device off
dark
steady lit
No status (requesting)
blinking
steady lit
No acceptable reference for monitored lines
steady lit
dark
Device is monitoring, no faults
steady lit
steady lit
Device is monitoring, line or amplifier faults
steady lit
blinking
Upper limit exceeded for monitored lines
ON
FAULT
(red)
(green)
Содержание MT 7308