10
ENGLISH
Digital address setting through DIP-switches:
DIP 5:
not used.
DIP 6:
faulty line switch off-relays (OFF: disabled, ON: enabled).
DIP 7:
not used.
DIP 8:
automatic spare amplifier insertion (OFF: disabled, ON: enabled).
ADDRESS
DIP-SWITCHES
ADDRESS
DIP-SWITCHES
1
2
3
4
1
2
3
4
1
ON
OFF OFF OFF
9
ON
OFF OFF
ON
2
OFF
ON
OFF OFF
10
OFF
ON
OFF
ON
3
ON
ON
OFF OFF
11
ON
ON
OFF
ON
4
OFF OFF
ON
OFF
12
OFF OFF
ON
ON
5
ON
OFF
ON
OFF
13
ON
OFF
ON
ON
6
OFF
ON
ON
OFF
14
OFF
ON
ON
ON
7
ON
ON
ON
OFF
15
ON
ON
ON
ON
8
OFF OFF OFF
ON
-
-
-
-
-
3
DATA:
‘Local Bus’ input. Link this port to the MU 7100EN local bus.
4
LINK:
‘Local Bus’ parallel output.
Содержание MT 7308