background image

7

ENGLISH

8 4

6 2

7 3

5 1

RJ 45 PLUG

RJ 45 SOCKET

| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |

POWER SUPPLY INPUT:

input for the external 24 V dc adapter (500 mA, i.e. optional RCF AC AD 
2405), not included.

NOTE:

 

the

 

first

 

paging

 

microphone

 

of

 

each

 

bus

 

can

 

be

 

used

 

for

 

emergency

 

purposes

. i

n

 

this

 

case

the

 

paging

 

microphone

 

shall

 

be

 

directly

 

powered

 

by

 

the

 dXt 9000 

system

 

main

 

unit

 (

no

 

need

 

of

 

an

 

eXternal

 

adapter

but

 

it

 

will

 

be

 

necessary

 

to

 

set

 

an

 

internal

 

switch

as

 

required

 

by

 

the

 en 54-16 

standard

.

WARNING:

 the internal switch setting shall be carried out only by either 

RCF or an authorised service centre.

First, remove the rear cover by unscrewing its 6 screws. 

BM 9802 SET FOR EMERGENCY PURPOSES

BM 9802 SET FOR 

EMERGENCY PURPOSES

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание BM 9802

Страница 1: ...USER MANUAL MANUALE D USO BM 9802 DXT 9000 DESK TOP PAGING MICROPHONE BASE MICROFONICA DA TAVOLO PER SISTEMA DXT 9000 www acornfiresecurity com www acornfiresecurity com...

Страница 2: ...www acornfiresecurity com www acornfiresecurity com...

Страница 3: ...PHONE SETTINGS display menu USE SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO PANNELLO FRONTALE IMPOSTAZIONI DELLA BASE MICROFONICA tramite men sul display UTILIZZO DATI...

Страница 4: ...tre 6 Should the paging microphone emit any strange odour or even smoke turn the sound system off immediately and disconnect it 7 RCF S p A strongly recommends the sound system installation is only ma...

Страница 5: ...ush To Talk PTT the General Call and the Chime On Off buttons Up to eight BE 9808 keyboards can be linked to every BM 9802 not used for emergency purposes Each BE 9808 has eight buttons that can be se...

Страница 6: ...luded REAR PANEL INPUT RJ 45 port to be linked to either a DXT 9000 main unit PAGING IN port or the previous paging microphone OUTPUT OUTPUT RJ 45 port to be linked to the next paging microphone INPUT...

Страница 7: ...microphone shall be directly powered by the DXT 9000 system main unit no need of an external adapter but it will be necessary to set an internal switch as required by the EN 54 16 standard WARNING th...

Страница 8: ...ount the rear cover Up to eight BE 9808 additional 8 zone button keyboards can be linked to every BM 9802 each powered by anACAD2405 adapter and not used for emergency purposes to increase the number...

Страница 9: ...cables linked to rear ports Pay attention to the flat cable right way indicated by its red wire see the figure Fix the first BE 9808 to the BM 9802 and all BE 9808 to one another by using the dedicate...

Страница 10: ...by the DXT 9000 system main unit no need of an external adapter but it will be necessary to set the internal switch as indicated in the previous manual section The emergency BM 9802 paging microphone...

Страница 11: ...n push to select all zones 9 LED GEN CALL green when lit it indicates the general call selection by pushing the GEN CALL 8 button 10 ALARM button it can be enabled only on paging microphones for emerg...

Страница 12: ...t in the paging microphone 16 G FLT Yellow One or more faults are detected in the system 17 EVAC Red An evacuation event is in progress 18 ALERT Yellow An alert event is in progress 19 BUSY Yellow The...

Страница 13: ...push it to confirm PASSWORD INSERTION Insert the correct password to access all parameters Push the rotary encoder 12 once Turn it clockwise so that the index displayed on the right is on Password th...

Страница 14: ...ible to select zones or groups combined with their buttons 2 Press and hold down the PTT button 6 3 If the zone selection is accepted wait a few seconds during the chime playing if previously enabled...

Страница 15: ...rophone sensitivity Frequency response Dimensions Gooseneck length Net weight electret cardioid 470 1 kHz 65 dB 3 dB 0 dB 1V bar 1 kHz 50 Hz 18 kHz 3 dB 128 x 39 x 203 mm without gooseneck 445 5 mm 1...

Страница 16: ...buildings 7 3 7 6 2 7 7 2 7 8 7 9 8 3 9 10 11 12 13 14 Audible warnings Manual silencing of the voice alarm condition Manual reset of the voice alarm condition Output to fire alarm devices Voice alarm...

Страница 17: ...ERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO PANNELLO FRONTALE IMPOSTAZIONI DELLA BASE MICROFONICA tramite men sul display UTILIZZO DATI TECNICI 18 19 20 25 26 28 29 www acornfiresecurity com www...

Страница 18: ...ori anomali od addirittura fumo spegnere immediatamente il sistema audio e scollegarla 7 RCF S P A raccomanda vivamente che l installazione del sistema audio sia eseguita solamente da installatori pro...

Страница 19: ...una delle seguenti funzioni selezione di zone o gruppi di zone richiamo di configurazioni preset incrementare o diminuire il volume della musica di sottofondo disattivare mute o riattivare la diffusio...

Страница 20: ...o 5 m con connettori RJ 45 PANNELLO POSTERIORE INPUT ingresso presa RJ 45 per il collegamento di una porta PAGING IN dell unit centrale del sistema DXT 9000 oppure alla presa OUTPUT della base microfo...

Страница 21: ...ente alimentata dall unit centrale del sistema DXT 9000 non serve l alimentatore esterno ma occorre impostare correttamente il selettore interno come richiesto dalla normativa EN 54 16 ATTENZIONE l im...

Страница 22: ...ia bus Successivamente rimontare il coperchio posteriore Ogni base microfonica BM 9802 se non usata per funzioni d emergenza pu essere espansa con massimo otto pulsantiere aggiuntive BE 9808 ciascuna...

Страница 23: ...t cable da fissare alle porte posteriori Prestare attenzione al verso corretto dei cavetti indicato dal filo rosso vedere la figura Fissare la prima BE 9808 alla BM 9802 e tutte le BE 9808 tra loro us...

Страница 24: ...e del sistema DXT 9000 non serve l alimentatore esterno ma occorre impostare correttamente il selettore interno come indicato nella sezione precedente del manuale Le basi microfoniche aventi funzione...

Страница 25: ...GEN CALL verde se acceso indica la selezione in corso della chiamata generale tramite il rispettivo tasto 8 10 Tasto ALARM pu essere abilitato solo nelle basi microfoniche con funzione d emergenza se...

Страница 26: ...ili inglese italiano tedesco e francese I primi tre contrasto scelta della lingua e password e l uscita dal men sono sempre accessibili mentre le altre impostazioni richiedono prima l inserimento dell...

Страница 27: ...il men verso l alto o per decrementare il valore del parametro selezionato Premerlo di nuovo per selezionare un parametro o per confermare un valore e ritornare al men SCELTA DELLA LINGUA Per selezio...

Страница 28: ...e o gruppi abbinate ai loro tasti 2 Premere e tener premuto il tasto PTT 6 3 Se la selezione delle zone stata accettata attendere pochi secondi la riproduzione del tono di preavviso se precedentemente...

Страница 29: ...sibilit microfono Risposta in frequenza Dimensioni Lunghezza flessibile Peso netto elettrete cardioide 470 1 kHz 65 dB 3 dB 0 dB 1V bar 1 kHz 50 Hz 18 kHz 3 dB 128 x 39 x 203 mm senza flessibile 445 5...

Отзывы: