RCF BD2412BS Скачать руководство пользователя страница 12

12

ENGLISH

Install  the  loudspeaker  through 
the  5.5  mm  holes  present  on  its 
mounting bracket. 
Make connections as described

CONNECTIONS

WARNING:

 loudspeaker connections should only be made by qualified and 

experienced personnel having the technical know-how or sufficient specific 
instructions to ensure that connections are made correctly and to prevent any 
electrical danger.
To prevent any risk of electric shock, do not connect loudspeakers when the 
amplifier is switched on.
Before turning the system on, check all connections and make sure there are 
no accidental short circuits.
The entire sound system shall be designed and installed in compliance with 
the current local laws and regulations regarding electrical systems.
The  internal  transformer  allows  the  connection  to  70  V  or  100  V  constant 
voltage  lines  and  the  power  selection  (during  the  installation)  among  the 
values 12 W - 6 W – 3 W.
The  speaker  is  designed  for  connection  to  audio  lines  at  70  V  or  100  V 
constant voltage. The connection to the audio line is made using the 4-wire 
input cable which leads from the back part of the speaker (fig. 1) The wires 
to be used depend on the line voltage and the power to be delivered, as 
indicated in the table below.

The selection is made considering the wire colours.

ITEM COLOR

POWER

VOLTAGE

IMPEDENCE

A

BLACK (-)

Common Wire

B

BROWN (+)

12 W

100 V

833 Ω

6 W

70 V

833 Ω

C

BLUE (+)

6 W

100 V

1667 Ω

3 W

70 V

1667 Ω

D

GREY (+)

3 W

100 V

3333 Ω

1.5 W

70 V

3333 Ω

Содержание BD2412BS

Страница 1: ...the rules of sound BD2412BS User manual Manuale d uso PROIETTORE BIDIREZIONALE IN ALLUMINIO ALUMINIUM BIDIRECTIONAL PROJECTOR ...

Страница 2: ......

Страница 3: ...tà 5 Impedire che oggetti o liquidi entrino all interno del prodotto perché potrebbero causare un corto circuito 6 Non eseguire sul prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando Il diffusore non funziona o funziona in modo anomalo il cavo è danneggiato ogget...

Страница 4: ...tire una corretta riproduzione audio soprattutto quando i diffusori sono collocati in posizione fra loro adiacente o nello stesso ambiente 13 Per evitare che fenomeni induttivi diano luogo a ronzii disturbi e compromettano il buon funzionamento dell impianto le linee diffusori non devono essere canalizzate insieme ai conduttori dell energia elettrica ai cavi microfonici alle linee di segnale a bas...

Страница 5: ...alla normativa BS 5839 8 COLORE grigio chiaro APPLICAZIONI I proiettori di suono sono facilmente orientabili Il loro impiego è consigliabile per sonorizzare grandi aree quali ad esempio supermarket stazioni ferroviarie metropolitane fabbriche magazzini impianti PA ecc ed in tutti quegli ambienti dove è richiesta una buona qualità di riproduzione ed un alta efficienza INSTALLAZIONE ATTENZIONE l ins...

Страница 6: ...iti accidentali Tutto l impianto di sonorizzazione dovrà essere realizzato in conformità con le norme e le leggi vigenti in materia di impianti elettrici Il trasformatore interno permette il collegamento a linee con tensione costante 70 V o 100 V e la selezione della potenza durante l installazione tra i valori 12 W 6 W 3 W Il diffusore è stato progettato per essere collegato a linee audio a tensi...

Страница 7: ...di tutti i diffusori in fase Utilizzare dei cavi con conduttori aventi una sezione adeguata considerando la loro lunghezza e la potenza complessiva dei diffusori Per evitare che fenomeni induttivi diano luogo a ronzii disturbi e compromettano il funzionamento del sistema i cavi per i diffusori non devono essere canalizzati assieme ai conduttori dell energia elettrica ai cavi microfonici od altre l...

Страница 8: ...l diffusore Potenza nominale continua 12 W 100 V 3 6 12 W 70 V 1 5 3 6 W Potenza massima 48 W Sensibilità 1 m 1 W 91 dB Risposta in frequenza 150 20 000 Hz Massima Pressione sonora 102 dB 1 m potenza max Tensione di Ingresso 70 V 100 V Angolo di copertura 6 dB 130 500 Hz 160 1 kHz 70 2 kHz 60 4 kHz Grado di protezione IP 55 IEC 529 Sistemi Voce Allarme BS 5839 Part 8 Selezione della Potenza Cavo a...

Страница 9: ...difications or repairs that are not expressly described in this manual Contact your authorized service centre or qualified personnel should any of the following occur the loudspeaker does not function or works in an anomalous way the cable has been damaged objects or liquids have got into the unit the loudspeaker has been damaged due to heavy impacts fire 7 Should the loudspeaker emit any strange ...

Страница 10: ...the amplifier polarity This is important when loudspeakers are installed adjacent one another for instance in the same room 13 To prevent inductive effects from causing hum noise and a bad system working loudspeaker lines should not be laid together with other electric cables mains microphone or line level signal cables connected to amplifier inputs 14 The loudspeaker cable shall have wires with a...

Страница 11: ...ormance Excellent reproduction of the music BD 2412BS is complying with BS 5839 8 standard COLOUR light grey APPLICATIONS Sound projectors can be easily aimed to any direction Their use is recommended in supermarkets railway stations subways parking lots factories warehouses PA system etc and in all environments where good sound quality and high efficiency are required INSTALLATION WARNING loudspe...

Страница 12: ...ned and installed in compliance with the current local laws and regulations regarding electrical systems The internal transformer allows the connection to 70 V or 100 V constant voltage lines and the power selection during the installation among the values 12 W 6 W 3 W The speaker is designed for connection to audio lines at 70 V or 100 V constant voltage The connection to the audio line is made u...

Страница 13: ...re connected in phase to ensure a correct audio reproduction Always use cables having wires with an adequate cross section considering the cable length and the total loudspeaker power Loudspeaker lines must be kept separated from mains cables microphone cables or others in order to avoid inductive phenomena may cause hum or noises Use cables with twisted wires to reduce hum caused by inductive eff...

Страница 14: ...0 000 Hz Maximum sound pressure 102 dB 1 m max power Input voltage 70 V 100 V Angle of coverage 6 dB 130 500 Hz 160 1 kHz 70 2 kHz 60 4 kHz Protection level IP 55 IEC 529 Voice Alarm system BS 5839 Part 8 Power selection 4 wire cable Connection cable length 1 m Dimension ø x p ø 146 mm x 186 mm Weight 3 2 kg Test lasting 24 hours with IEC spectrum Grey Blue Brown 0 Black Black Black 100 V 100 V 12...

Страница 15: ......

Страница 16: ...74484 e mail rcfservice rcf it Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF S p A reserves the right to make modifications without prior notice 10307083 the rules of sound 10307140 A ...

Отзывы: