![RCA RACE5002E Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/rca/race5002e/race5002e_owners-manual_17400014.webp)
4. TIMER SET button (Timer range: 1-24 hours)
5. TEMPERATURE ADJUSTMENT button
FUNCTION SPECIFICATIONS
6.
AIR FLOW DIRECTION ADJUSTMENT
13
13
Moving the wheel on the front grille of the unit , the airflow can be directed to the left, right, straight ahead,
or any combination of these directions.
OPERATING INSTRUCTIONS
Notice: The time of AUTO-OFF will be displayed for 10 seconds , after that the display will change to
display the set temperature but in fan mode the room temperature will be displayed.
1) When the unit is on, press this button once to start timer off function and “01” will be shown on the
display ,every press of this button increases the AUTO-OFF time by 1 hour(24 hours at most), when the
time accumulates to 24 , press this button again the air conditioner will quit timer function. You can refer
to the following:
01 02
quit timer function.
…
24
2) When the unit is off, press this button once to start timer on function and “01” will be shown on the
display ,every press of this button increases the AUTO-ON time by 1 hour(24 hours at most), when the
time accumulates to 24 , press this button again the air conditioner will quit timer function. You can refer to
the following: When the timer on is activated the timer indicator
lamp and the relative mode indicator lamps will flash and other buttons on the control panel are not
functional , modes can be changed by pressing the buttons on the remote controller.
Notice: AUTO-ON time will be displayed all the time before the air conditioner is turned on.
3) The display of AUTO-ON/OFF time will be decreased by one hour.
01 02
quit timer function.
…
24
Button: When the unit is on, at cool mode the set temperature is displayed on the display all along .
Press button once the set temperature will increase 1
°
F(1
), every press of this button increases the
set temperature by 1
°
F(1
). The range of setting temperature is limited to 88
°
F(31
). At fan mode, button
is not functional.
Button: When the unit is on, at cool mode the set temperature is displayed on the display all along .
Press button once the set temperature will decrease 1
°
F(1
), every press of this button decreases the
set temperature by 1
°
F(1
). The range of setting temperature is limited to 61
°
F(16
). At fan mode, button
is not functional.
1. COOL RUNNING
1). Initial set temperature is 79 (26
).
F
2). 3-minute time delay function of the compressor. When the setting temperature is lower than the room
temperature, the compressor starts; when the setting temperature is higher than the room temperature
the compressor stops.
3). The range of setting temperature is 61 -88
.
(16
-31
)
F
F
4). Both fan speed and air flow direction are adjustable.