Environmental Requirements  

The location of your transceiver and the layout of the environment are important considerations for proper 
operation. Equipment placed too close together, inadequate ventilation, and inaccessible enclosures can 
cause malfunctions and shutdowns, and can make maintenance difficult.  
 
Install the transceiver so that you can access both the bottom for power and data connections, and the top for 
the antenna connection. Ensure that the enclosure door can be opened far enough for easy access to the 
interior of the device. 
 
If you are currently experiencing shutdowns or an unusually high number of data errors with your existing 
equipment, these precautions and recommendations may help you isolate the cause of failure and prevent 
future problems: 
 

Ensure that the location has adequate air circulation. Electrical equipment generates heat. Without 
adequate air circulation, ambient air temperature may not cool equipment to acceptable operating 
temperatures.   
 

Always follow ESD-prevention procedures described in the Preventing Electrostatic Discharge 
Damage to avoid damage to equipment. Damage from static discharge can cause immediate or 
intermittent equipment failure.   
 

Ensure that the chassis cover and cable glands are secure and water-tight. 
 

Ensure that the antenna is fully connected (finger tight is adequate) and the antenna connection is 
free of moisture and debris. 

 

DO NOT OVERTIGHTEN CABLE GLANDS.  DO NOT OVERTIGHTEN THE ANTENNA. 
Finger tight is adequate. 
 

Power Guidelines and Requirements  

Check the power at your site to ensure that you are receiving “clean” power (free of spikes and noise). Install 
a power conditioner if necessary.  
 
The RC5 EASS IP65 transceiver uses a fully isolated Class 2 power supply module.  The class 2 power 
supply is internationally safety certified* for AC voltage input within the range of 100VAC to 240VAC.  No 
manual selection of input voltage is required. 
 
The NEMA enclosure for the RC5 EASS IP65 is non-conductive and poses no electric shock hazard when 
fully closed and latched. 
 

Warning: 

Enclosure must be closed when device is in use.  Access must be controlled with a lock on 

the chassis door, or access to the installation area must be controlled. 
 
 
* Meanwell APV-12-12 Class 2 power supply is certified to UL8750, CSA C22.2 No.250.0-08, ENEC BIS 
IS15885, EN61347-1, EN61347-2-13, EN62384 Independent, EAC TP TC 004 IP42 approved. 

 

 

Содержание RC5 EASS IP65

Страница 1: ...RC4 Wireless RC5 EASS IP65 Installation Safety and Site Preparation Guide c 2018 RC4 Wireless All rights reserved Rev 1 1A ...

Страница 2: ...ptional Accessories Not Included 9 Main Power Connection 10 Data Cable Connection 11 Antenna Connection 12 Device Configuration 13 Automatic Transmit Receive Functionality 14 Contact RC4 Wireless 14 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warning Ultimate disposal of this product should be handled according to all national laws an...

Страница 3: ...a suitable padlock not included Warning The RC5 enclosure prevents exposure to hazardous voltages and currents inside Do not operate the system unless all circuit boards components and covers are in place and the enclosure cover is closed and latched Warning Read all installation instructions before connecting the system to the power source Warning IMPORTANT SAFETY INSTRUCTIONS Before you work on ...

Страница 4: ...turn off the power Disconnect all power before doing the following Installing or removing a chassis Working near power supplies Look carefully for possible hazards in your work area such as moist floors ungrounded power extension cables frayed power cords and missing safety grounds Do not work alone if hazardous conditions exist Never assume that power is disconnected from a circuit Always check N...

Страница 5: ...he safety of your equipment periodically check the resistance value of the antistatic strap It should be between 1 and 10 megohms Mohm General Site Requirements This section describes the requirements your site must meet for safe installation and operation of your RC4 Wireless transceiver Ensure that the site is properly prepared before beginning installation If you are experiencing shutdowns or u...

Страница 6: ... damage to equipment Damage from static discharge can cause immediate or intermittent equipment failure Ensure that the chassis cover and cable glands are secure and water tight Ensure that the antenna is fully connected finger tight is adequate and the antenna connection is free of moisture and debris DO NOT OVERTIGHTEN CABLE GLANDS DO NOT OVERTIGHTEN THE ANTENNA Finger tight is adequate Power Gu...

Страница 7: ...vers should be positioned for the shortest possible distance between antennas with the fewest obstacles in the line of sight path between antennas Omnidirectional antennas sometimes called whip antennas should be oriented vertically with the tip pointing directly upward or downward For other types of antennas follow instructions provided with them Higher elevation of antennas improves range This i...

Страница 8: ...supply RP SMA antenna connection 2 conductor Wago connector for AC power connections pre attached to internal power supply input wires AC power cable gland suitable for 5 11mm diameter cable Data cable gland suitable for 3 6mm diameter cable 900MHz omnidirectional dipole antenna 19cm long articulated base RP SMA connector Wall mount kit consisting of 4 small brackets and screws ...

Страница 9: ...larging gland holes be sure to remove ALL resulting debris from the RC5 EASS IP65 enclosure when done Avoid contaminating the RC5 enclosure with metal particles on drill bits and other tools The following are available at additional cost Alternative antennas including high gain directional Yagi panel and more Antenna extension cables for mounting an antenna some distance from the RC5 enclosure Pol...

Страница 10: ...w instructions and procedures provided by Wago for part number 222 412 Keep internal AC wiring short and neat without excess length within the RC5 EASS IP65 enclosure Cable tie the incoming AC wiring to the Class 2 power supply wiring in a position that ensures the Wago connector remains below the power supply within the power wiring area outlined by white lines on the circuit board Important Remo...

Страница 11: ...olarity If using RJ45 connections it may be necessary to crimp the connector to the data cable after passing it through the cable gland There is no performance advantage to either the screw terminals or the RJ45 connectors They are connected in parallel If passing DMX data through the RC5 to other devices the input and output can be either through screw terminals or RJ45 connectors The connections...

Страница 12: ...onnector at the top of the enclosure Caution ONLY approved 900MHz antennas may be used with RC5 EASS IP65 transceivers A list of appropriate antennas is available from RC4 Wireless Connect the provided antenna by threading the base of the antenna onto the connector on the top of the enclosure FINGER TIGHT IS ADEQUATE DO NOT OVERTIGHTEN THE ANTENNA Omnidirectional dipole antennas should be oriented...

Страница 13: ...evices are not operating as expected it is often best to Restore Factory Defaults With the device powered on Press and hold the Func button Tap the ID3 Set Defaults button Release the Func button When the buttons are released the left most LEDs yellow and green will blink several times together followed by a device restart RC5 devices can be accessed and configured remotely by wireless using RC4 C...

Страница 14: ...ll behave as a wireless data receiver and output wired DMX data on the wired DMX connections Otherwise if wired DMX data is present at the DMX data cable connections the transceiver will behave as a transmitter and broadcast wireless DMX data to receivers Contact RC4 Wireless Your satisfaction is very important to us Do not hesitate to contact us for assistance RC4 Wireless 13604 Heathwood Court R...

Отзывы: