away from contaminated areas.

1. Combustible/

fl

 ammable materials -- 

Do not store combustible materials, 

gasoline or any other 

fl

 ammable 

vapors or liquids near the boiler. 

Remove immediately if found.

2. Air contaminants -- Products 

containing chlorine or 

fl

 uorine, 

if allowed to contaminate the 

heater intake air, will cause acidic 

condensate in the heater. This 

will cause signi

fi

 cant damage to 

the heater if allowed to continue. 

Read the list of potential materials 

listed in Section 4.1. If any of these 

products are in the room from which 

the heater takes its combustion air, 

they must be removed immediately 

or the heater combustion air (and 

vent termination) must be relocated 

to another area.

6.1.3 - Check pressure 
gauge

1. Make sure the pressure reading on 

the heater pressure gauge (item “M” 

of Figure 5-1) does not exceed the 

maximum working pressure. Higher 

pressure may indicate a problem 

with the expansion tank.

2. Contact a quali

fi

 ed service 

technician if problem persists.

6.1.4 - Check vent piping

1. Visually inspect the vent outlet 

termination to be sure it is 

unobstructed. Visually inspect the 

entire length of the 

fl

 ue gas vent 

piping for any signs of blockage, 

leakage, or deterioration of the 

piping. Notify your quali

fi

 ed service 

technician at once if you 

fi

 nd any 

problems.

WARNING!!!

 Failure 

to inspect the vent system 
as noted above and have it 
repaired by a qualifi ed service 
technician can result in vent 
system failure, causing severe 
personal injury or death.

6.1.1 - Check relief valve

Inspect the relief valve and lift the 

lever to verify 

fl

 ow. Before operating 

any relief valve, ensure that it is piped 

with its discharge in a safe area to 

avoid severe scald potential. Relief 

valve should be re-inspected at least 

once every three years, by a licensed 

plumbing contractor or authorized 

inspection agency, to ensure that 

the product has not been affected 

by corrosive water conditions and to 

ensure that the valve and discharge 

line have not been altered or tampered 

with illegally.

Certain naturally occurring conditions 

may corrode the valve or its 

components over time, rendering the 

valve inoperative. Such conditions are 

not detectable unless the valve and its 

components are physically removed 

and inspected. This inspection must 

only be conducted by a plumbing 

contractor or authorized inspection 

agency – not by the user.

WARNING!!!

 Failure to 

re-inspect the relief valve as 
directed could result in unsafe 
pressure buildup, which can 
result in severe personal injury, 
death, or substantial property 
damage.

6.1.2 - Check heater area

WARNING!!!

 To prevent 

potential of severe personal 
injury, death, or substantial 
property damage, eliminate 
all materials discussed below 
from the heater vicinity and 
the vicinity of the heater 
combustion air inlet. 

If contaminants are found: 
Remove products immediately 
from the area. If they have 
been there for an extended 
period, call a qualifi ed service 
technician to inspect the 
heater for possible damage 
from acid corrosion. 

If products cannot be removed, 
immediately call a qualifi ed 
service technician to re-pipe 
vent and air piping and locate 
vent termination/air intake 

6 - MAINTENANCE

Содержание infinite energy 2

Страница 1: ...uction Construction dust and particulate particularly drywall dust will cause contamination of the burner resulting in possible severe personal injury death or substantial property damage The boiler c...

Страница 2: ...any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation...

Страница 3: ...3...

Страница 4: ...ivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au...

Страница 5: ...5 SAFETY INSTRUCTIONS...

Страница 6: ...th WARNING Qualified installer qualified installer is an individual with specific technical training in space heating systems domestic hot water systems fuel gas systems and electrical systems This in...

Страница 7: ...o so can cause severe personal injury or death NOTICE When calling or writing about the heater Please have the heater model and serial number from the heater rating plate NOTICE Any claims for damage...

Страница 8: ...r heater temperature adjustment 14 5 6 IB Heating temperature adjustment 14 5 7 Delays alarms and protective actions 15 5 8 Circulator pump protection 15 5 9 Freeze protection 15 5 10 Display in energ...

Страница 9: ...d Boilers ANSI ASME CSD 1 NOTICE Install CO detectors per local regulations NOTICE IB Boiler version meets the safety and other performance requirements as specified in ANSI Z21 13 standard NOTICE IW...

Страница 10: ...factured by RBI WATER HEATER 7555 Tranmere Drive Mississauga Ontario L5S 1L4 Canada Phone 905 670 5888 Fax 905 670 5782 www rbiwaterheaters com 2 3 Description of models XX XXXX 199 maximum power inpu...

Страница 11: ...87 when outside is 10 F 23 C to 94 8 when outside is 23 F 5 C and up to 98 when the outside temperature rises up to 67 F 20 C 3 1 Intended use and functions 3 1 1 Intended use and functions of the IB...

Страница 12: ...de used for thawing Sodium chloride used for water softening Refrigerant leaks Paint or varnish removers Hydrochloric acid muriatic acid Cements and glues Antistatic fabric softeners used in clothes d...

Страница 13: ...system pressure L Burner unit indicators Light when burner is burning blinking when burner is in lockout or in blocking error Burner 1 master Burner 2 Burner 3 Burner 4 M Water pressure gauge and indi...

Страница 14: ...ay mode press and hold for at least 5 seconds RESET key The heater will automatically attempt another start up CAUTION If the appliance frequently shuts down contact a qualified technician to restore...

Страница 15: ...ter demand is satisfied a 4 minutes delay must pass before the end of the service e Time delay in restarting the burner in its normal functioning state every time the burner stops there is a delay tim...

Страница 16: ...min 1041 Burner 1 Ignition fan speed rpm min 1042 Burner 1 Low power fan speed rpm min 1043 Burner 1 High power fan speed rpm min 1051 Burner 1 Last lockout number 1052 Burner 1 Last Blocking error 1...

Страница 17: ...l injury or death 5 14 Shuts heater down 1 Follow To Turn Off Gas to Appliance on page 3 of this manual 2 Do not drain the system unless exposure to freezing temperatures will occur 3 Do not drain the...

Страница 18: ...d technician in accordance with all applicable local and national codes Improper servicing or adjustment could damage the boiler Failure to comply with this warning can result in a fire or explosion c...

Страница 19: ...voir and fill with fresh water Clean air filter Check the capacity input Check relief valve Daily Check heater area Follow section 6 1 2 Check pressure gauge Follow section 6 1 3 Monthly Check vent pi...

Страница 20: ...th 6 1 1 Check relief valve Inspect the relief valve and lift the lever to verify flow Before operating any relief valve ensure that it is piped with its discharge in a safe area to avoid severe scald...

Страница 21: ...r and system 6 1 7 Check heater piping gas and water 1 If gas odor or leak is detected immediately shut down the heater following the procedures on page 3 Call a qualified service technician 2 Visuall...

Страница 22: ...22 NOTE...