17
5 - USE
5.12 - Diagnostic
During normal operation display can show the below
informations:
5.13 - Safety fl ue
blocked pressure
switch
This appliance is equipped with a
safety
fl
ue blocked pressure switch
that shut-off the unit when the
fl
ue
exhaust vent pipe is blocked. If this
pressure switch shuts off the unit (Loc
5 or Loc 25), do not attempt to place
the heater in operation but contact a
quali
fi
ed service agency.
To reset the blocked vent shut off
system, call a quali
fi
ed service agency
that will reset the unit after checking
for any potential dangerous situation.
WARNING!!!
If the safety
fl ue blocked pressure switch shuts
off the system do not attempt
to reset or repair the unit. It is
mandatory to contact an Qualifi ed
service agency. Failure to comply
with this requirement can result
in excessive levels of carbon
monoxide which can result in
severe personal injury or death!
5.14 - Shuts heater
down
1. Follow “To Turn Off Gas to
Appliance” on page 3 of this
manual.
2. Do not drain the system unless
exposure to freezing temperatures
will occur.
3. Do not drain the system if it is
fi
lled
with an antifreeze solution.
5.15 - How to clean
the appliance
jacket
To clean the appliance jacket, use only
a soft cloth dampened with water. Do
not use aggressive or abrasive agents.
Parameter
Parameter description
Visualization on display “N” (see Figure 5-1)
AFro
Heater is doing antifreezing protection
Supply temperature (°F)
Light fi xed = Indirect water heater enabled
Blinking = indirect water heater loading
Supply temperature (°F)
Light fi xed = Hot water supply enabled
Blinking = Hot water supply active
Supply temperature (°F)
Loc
Heater is in Lockout. Press RESET button to unlock the burner.
If lockout happens frequently, ask for a qualifi ed technical
service
Lock out code
Err
Heater is in blocking error. It is possible to restore the normal
operating conditions only resolving the problem. Ask for a
qualifi ed technical service.
Blocking error code