Read all instructions thoroughly,
and perform regular maintenance
and service as directed. Keep this
manual on or near the boiler.

 

This manual is intended only for use by a quali

fi

 ed heating installer/technician. Read and follow this manual, all supplements and 

related instructional information provided with the boiler. Install, start and service the boiler only in the sequence and methods 
given in these instructions. Failure to do so can result in severe personal injury, death or substantial property damage.

 

Do not use the boiler during construction.

 

Construction dust and particulate, particularly drywall dust, will cause contamination 

of the burner, resulting in possible severe personal injury, death or substantial property damage.  The boiler can only be operated with 
a dust-free air supply. Follow the instruction manual procedures to duct air to the boiler air intake. If the boiler has been contaminated 
by operation with contaminated air, follow the instruction manual guidelines to clean, repair or replace the boiler if necessary.

 

Af

fi

 x these instructions near to the boiler. Instruct the building owner to retain the instructions for future use by a quali

fi

 ed service 

technician, and to follow all guidelines in the User’s Information Manual.

Condensing, 
High Effi ciency 
Water Heaters (IW) 
and Boilers (IB)

62417021 R00 Feb. 18, 2014

Содержание infinite energy 2

Страница 1: ...uction Construction dust and particulate particularly drywall dust will cause contamination of the burner resulting in possible severe personal injury death or substantial property damage The boiler c...

Страница 2: ...any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation...

Страница 3: ...3...

Страница 4: ...ivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au...

Страница 5: ...5 SAFETY INSTRUCTIONS...

Страница 6: ...th WARNING Qualified installer qualified installer is an individual with specific technical training in space heating systems domestic hot water systems fuel gas systems and electrical systems This in...

Страница 7: ...o so can cause severe personal injury or death NOTICE When calling or writing about the heater Please have the heater model and serial number from the heater rating plate NOTICE Any claims for damage...

Страница 8: ...r heater temperature adjustment 14 5 6 IB Heating temperature adjustment 14 5 7 Delays alarms and protective actions 15 5 8 Circulator pump protection 15 5 9 Freeze protection 15 5 10 Display in energ...

Страница 9: ...d Boilers ANSI ASME CSD 1 NOTICE Install CO detectors per local regulations NOTICE IB Boiler version meets the safety and other performance requirements as specified in ANSI Z21 13 standard NOTICE IW...

Страница 10: ...factured by RBI WATER HEATER 7555 Tranmere Drive Mississauga Ontario L5S 1L4 Canada Phone 905 670 5888 Fax 905 670 5782 www rbiwaterheaters com 2 3 Description of models XX XXXX 199 maximum power inpu...

Страница 11: ...87 when outside is 10 F 23 C to 94 8 when outside is 23 F 5 C and up to 98 when the outside temperature rises up to 67 F 20 C 3 1 Intended use and functions 3 1 1 Intended use and functions of the IB...

Страница 12: ...de used for thawing Sodium chloride used for water softening Refrigerant leaks Paint or varnish removers Hydrochloric acid muriatic acid Cements and glues Antistatic fabric softeners used in clothes d...

Страница 13: ...system pressure L Burner unit indicators Light when burner is burning blinking when burner is in lockout or in blocking error Burner 1 master Burner 2 Burner 3 Burner 4 M Water pressure gauge and indi...

Страница 14: ...ay mode press and hold for at least 5 seconds RESET key The heater will automatically attempt another start up CAUTION If the appliance frequently shuts down contact a qualified technician to restore...

Страница 15: ...ter demand is satisfied a 4 minutes delay must pass before the end of the service e Time delay in restarting the burner in its normal functioning state every time the burner stops there is a delay tim...

Страница 16: ...min 1041 Burner 1 Ignition fan speed rpm min 1042 Burner 1 Low power fan speed rpm min 1043 Burner 1 High power fan speed rpm min 1051 Burner 1 Last lockout number 1052 Burner 1 Last Blocking error 1...

Страница 17: ...l injury or death 5 14 Shuts heater down 1 Follow To Turn Off Gas to Appliance on page 3 of this manual 2 Do not drain the system unless exposure to freezing temperatures will occur 3 Do not drain the...

Страница 18: ...d technician in accordance with all applicable local and national codes Improper servicing or adjustment could damage the boiler Failure to comply with this warning can result in a fire or explosion c...

Страница 19: ...voir and fill with fresh water Clean air filter Check the capacity input Check relief valve Daily Check heater area Follow section 6 1 2 Check pressure gauge Follow section 6 1 3 Monthly Check vent pi...

Страница 20: ...th 6 1 1 Check relief valve Inspect the relief valve and lift the lever to verify flow Before operating any relief valve ensure that it is piped with its discharge in a safe area to avoid severe scald...

Страница 21: ...r and system 6 1 7 Check heater piping gas and water 1 If gas odor or leak is detected immediately shut down the heater following the procedures on page 3 Call a qualified service technician 2 Visuall...