UNC100 Specification
Controller Power Requirements
12 – 14vdc
Current Consumption
250mA
Processor
32 bit micro controller
Memory
2MB
Panels per Network
16
HOST Ethernet speed
10/100 TCP/IP Ethernet, RS485 4 wire
HOST RS485 Speed
9600, 38400, 57600, 115200 baud
Clock/RAM backup battery
3v Lithium battery CR1632
Real Time Clock
Built-in as standard
Watch Dog Circuit
Built-in as standard
Board Dimensions
H 5½ in x W 5 in (14
x 12½ cm
)
Operating Temperature
0 to 70C (
35 - 150F
)
Operating Humidity
20 to 85% RH (
non-condensing
)
Cable Specification
Circuit Function
Cable type
Length
PC To Controller (Ethernet)
CAT5 communications cable
323 feet (100 meters)
PC To Controller (RS485)
Twisted pair, shielded, stranded
18 to 22 AWG
2000-4000 feet
(600-1200 meters)
Reader
20 to 22 AWG, 6 or 8-conductor,
stranded, shielded (
not twisted
)
500 feet (1
50 meters
)
Input / Output Port Circuit Loop
2-conductor, 20 to 22 AWG
1000 feet (
300 meters
)