In order to use the Paradox Virtual Input option the printer module must be
programmed to allow all 16 virtual inputs to be used and the inputs must be
programmed into the panel. An IOC16 must be added to Axiom with properties
set for all outputs and the address must match the Virtual IOC address set by the
PC100 dipswitch. Whenever a virtual output is turned on or off the
corresponding virtual input will open or close.
To use this feature apply a link to turn on or off the Virtual output in order to
communicate an open or closed zone on the alarm panel.
Virtual Input Programming
Follow the previous procedure for accessing the printer module programming
section (4003 followed by the device serial number).
Sections 700, 710, 720, 730, 740, 750, 760, 770, 780, 790, 800, 810, 820, 830,
840, 850 should be programmed for 1*******, the in-between sections should
remain defaulted.
Add the Virtual Inputs to the Alarm Panel
The virtual inputs from the printer module may be assigned to the alarm panel by
following the Zone Programming procedure in the programming guide. Not all of
the inputs have to be assigned.