4
Preparing Hot Water Line
Important
•
Plumbing must meet local codes and
ordinances. If plumbing does not, contact a
licensed plumber.
•
Hot water line must accommodate 3/8" copper
tubing or 1/2" plastic tubing. Manual shut-off in
hot water line is recommended.
1.
Cut 1 1/2" hole in cabinet for hot water line. Hot
water line must enter within shaded area.
Preparing Drain Plumbing
Important
•
Plumbing must meet local codes and
ordinances. If plumbing does not, contact a
licensed plumber.
•
Edges of cabinet opening for drain hose must be
smooth and rounded. If cabinet is metal, edges
of opening must be covered with a rubber cord
protector.
•
An air gap must be used if drain hose is
connected to house plumbing lower than 18"
above floor level. All air gap devices must be
capable of passing 3/8" steel ball to assure
minimum drain line stoppages.
5"
4"
2"
5"
Hot
4"
6"
2.
Flush water line to clean out debris.