background image

S

ta

ndal

one 

U

nit /

 Ma

s

te

Un

it i

n Dual

 Mod

e

Содержание ECDIS NX Compact

Страница 1: ...ECDIS NX Compact System Manual Edition 001 10000000559 ...

Страница 2: ... gestattet Zuwiderhandlungen verpflichten zu Schadenersatz This document and its content are copyright protected Distribution reproduction and storage as well as translation and exploitation of this document and its content in whole or in parts and regardless of what form are prohibited without prior express written permission Offenders will be held liable for the payment of damages Änderungen die...

Страница 3: ...l Data 8 1 8 List of Optional Equipment 9 2 Installation 10 2 1 Hardware Installation 10 2 1 1 General Installation Recommendations 10 2 1 1 1 Installation and Mounting 10 2 1 1 2 Installation Limitations 11 2 1 1 3 Ergonomics 12 2 1 1 4 Cables 12 2 1 1 5 Housing Terminal Block Connector Overview 14 2 1 1 6 Configuring Housing Terminal Block Connectors 15 2 1 2 Installation Procedures 17 2 1 2 1 I...

Страница 4: ...ECDIS NX Compact Table of Contents 10000000559 II Edition 001 ...

Страница 5: ...s and Washers 19 Fig 14 Position of Strain Relief Clamps 20 Fig 15 Strain Relief Clamp with Cable 20 Fig 16 Connection Area 21 Fig 17 Connection Overview Allocation of Pins 23 Fig 18 Connection Overview Allocation of Devices 24 Fig 19 Select Future Boot Type 26 Fig 20 Remove USB Flash Drive 27 Fig 21 Installation Window 28 Fig 22 Installation Complete 29 Fig 23 User Account Control Message 29 Fig ...

Страница 6: ...ECDIS NX Compact List of Figures 10000000559 IV Edition 001 ...

Страница 7: ... Performance Standards 3 Tab 2 IHO Standards 3 Tab 3 List of Further Operator Documents 4 Tab 4 List of Further System Documents 4 Tab 5 Optional Equipment Spare Parts 9 Tab 6 Allocation of Pins 23 Tab 7 Allocation of Devices Standalone Main Unit 25 Tab 8 Allocation of Devices Backup Unit 25 ...

Страница 8: ...ECDIS NX Compact List of Tables 10000000559 VI Edition 001 ...

Страница 9: ...gational Chart ETA Estimated Time of Arrival IEC International Electrotechnical Commission IHO International Hydrographic Office IMO International Maritime Organization INS Integrated Navigation System LAT Latitude LON Longitude LOP Line of Position MFC Multifunction Console MMSI Maritime Mobile Service Identity MOB Man Over Board NGA National Geospatial Intelligence Agency NOAA National Oceanic a...

Страница 10: ...ECDIS NX Compact List of Abbreviations 10000000559 VIII Edition 001 XTE Cross Track Error ...

Страница 11: ...com All rights reserved It is not allowed to copy any part of this manual neither mechanically electronically magnetically manually nor otherwise It is not allowed to store it in a database or distribute or forward it without written permission of Raytheon Anschütz GmbH Copyright Raytheon Anschütz GmbH Zeyestr 16 24 D 24106 Kiel Germany Errors can hardly be avoided in the documentation despite all...

Страница 12: ...ety Instructions WARNING Danger due to nonadherence to general rules and regulations Risk of death or serious injury and material damage Observe all national and regional rules and regulations Observe all general rules and regulations that are specified for the work area Observe all instructions that are placed on the components or described in related documentation WARNING Danger due to improper ...

Страница 13: ...ems Electronic chart display and information system ECDIS IEC 62288 Ed 2 Presentation of navigation related information on shipborne naviga tional displays IEC 62065 Ed 2 Maritime navigation and radiocommunication equipment and systems Track control systems The ECDIS is designed to meet the requirements as defined by IMO IEC and IHO The ECDIS is compliant with the following IHO standards Tab 2 IHO...

Страница 14: ...r Documents Tab 3 List of Further Operator Documents Documentation No Designation 4451 Conning NX 10000000351 ECDIS NX Tab 4 List of Further System Documents Documentation No Designation 4449 Synapsis System Manual 4428 Synapsis Service Tool 4450 Synapsis Radar NX Manual ...

Страница 15: ...atic Identification System AIS transponder Positioning devices Echo sounders Heading sensors Speed sensors The information is integrated into easily interpretable visual displays Note Chart Datum is World Geodetic System WGS 1984 For further information about features and functionality of the ECDIS software see ECDIS NX Operator Manual 1 2 Standalone and Dual Mode ECDIS NX Compact can be set up wi...

Страница 16: ...change from green to red or the image on screen disappears Brightness Adjust Brilliance Brightness adjustment of the displayed image is adjusted by touching the or illuminated symbols The entire area of text and symbols are visible as long as the unit is powered Note that only the and are touch sensitive while the symbols are not ECDIS Status Indicator For units that has been factory ECDIS calibra...

Страница 17: ...ional for units ordered with Buzzer functionality The location of the buzzer hole physical hole in glass is barely visible for the eye Touching this area will naturally mute buzzer sound or in some cases make it lower or change audible frequency In no circumstances should this area be blocked by either stickers or objects Light Sensor Used to sense level of ambient light in the surrounding environ...

Страница 18: ...ct the extension cord to the USB 3 0 port and lead the connector somewhere where it is reachable after the installation for later updates via USB Charts The chart installation and update is organized via the 7Cs ChartHandler see ECDIS NX Operator Manual 1 6 Dependence on Peripheral Systems Devices The normal ECDIS NX Compact operation depends on following systems and devices Position sensor e g GP...

Страница 19: ...operating temperature of 55 C conti nous operation of all electronic components should if possible take place at ambient temperatures of only 25 C This is a necessary prerequisite for long life and low service costs Storage Temperature 20 C to 60 C Humidity up to 95 IP Rating IP66 front IP22 rear EN60529 Compass Safe Distance Standard 115 cm Steering 70 cm Display Specifications Size 24 0 inch Wid...

Страница 20: ...are not permissible 3 Generally do not install the unit in a horizontal position laying down as this will cause heat to build up inside the unit which will damage the LCD Panel To prevent this problem we recommend installing the unit in a vertical position 30 degrees to improve the airflow through the unit 4 To further improve the thermal situation we recommend to use forced air passing by the pro...

Страница 21: ...have internal fans providing additional cooling airflow of their own In such cases the 30 vertical angle may in certain situations allow for lower angle mounting provided that the console casing has adequate cooling see point D however this is suggested as a trouble shooting tip during installation or during shortterm observer use if found suitable It should not be considered as a defintive truste...

Страница 22: ...reen 3 Adjust screen inclination to remain gaze angle to the centre of the screen approximately perpendicular to the line of gaze 4 When products are to be operated both from a sitting position and from a standing position a screen inclination of about 30 to 40 from a vertical plane has turned out to be favourable 5 The brightness of displays is limited Sunlight passing directly through the bridge...

Страница 23: ...he delivery of ECDIS NX Compact Connect the extension cord to the USB 3 0 port and lead the connector somewhere where it is reachable after the installation for later updates via USB Cable Entries Connectors Marked area Illustration below for similar panel pc Fig 4 Panel PC Cable Entries Connectors Back ...

Страница 24: ...n Only skilled electricians must perform work on the electric system Keep moisture away from live parts Keep the system closed Do not attempt to bypass or disable fuses Housing Terminal Block connectors are available in different sizes example 2 pin 4 pin 5 pin which plugs into the connector area of the unit They are mounted by factory default and delivered with the unit The housing terminal block...

Страница 25: ...ified on Hatte land Display prod uct data sheet as Terminal Block 3 81 2 1 1 6 Configuring Housing Terminal Block Connectors About this task Below is a brief illustration that might be useful during configuration and installation of such connectors You will need suitable pre configured cable s and tools to configure the connector s and cable s that are present in your installation environment Belo...

Страница 26: ...tly Note Note Required polarization verification for instance for DC power input should conform with the markings on the connector area of the unit Ignoring the markings on the unit or its add on modules might damage the unit and or external equipment in which end warranty will be void Fig 7 Connector Insert Cables 3 Plug the housing into the appropriate connector area of the unit glass should be ...

Страница 27: ...2 1 Install the Unit into a Console About this task WARNING Danger due to voltage regulated devices Risk of death or serious injury that is caused by electrical shock Switch off voltage supply if the wires have damaged insulation Only skilled electricians must perform work on the electric system Keep moisture away from live parts Keep the system closed Do not attempt to bypass or disable fuses You...

Страница 28: ...should be facing downwards Fig 10 Installation Slide Unit into Cutout 2 Make sure you are aware that brackets should be mounted on Top Left Right and Bottom sides Note that the B bracket is different than the A brackets and mounted near the connectors See closeup of details Fig 11 Installation Use Correct Brackets 3 Secure each bracket with the provided M5x16 screws and C Washers as illustrated be...

Страница 29: ...elding and Strain Relief WARNING Danger due to voltage regulated devices Risk of death or serious injury that is caused by electrical shock Switch off voltage supply if the wires have damaged insulation Only skilled electricians must perform work on the electric system Keep moisture away from live parts Keep the system closed Do not attempt to bypass or disable fuses ECDIS NX compact is equipped w...

Страница 30: ...X Compact 2 Installation 10000000559 20 Edition 001 Fig 14 Position of Strain Relief Clamps Turn the cable shield over the coating and fix it with the strain relief clamp Fig 15 Strain Relief Clamp with Cable ...

Страница 31: ...res have damaged insulation Only skilled electricians must perform work on the electric system Keep moisture away from live parts Keep the system closed Do not attempt to bypass or disable fuses Note To reduce tension of the cables you connect secure them with the strain relief clamps as described in chapter chapter 2 1 2 2 1 Fig 16 Connection Area Connector Description USB 3 0 Input Output Suppor...

Страница 32: ...nnector Power Input DC Connect your DC power cable to the 2 pin Terminal Block 5 08 con nector The internal DC power module supports 24 V DC Power Input AC The internal AC power module supports both 115VAC 60Hz and 230VAC 50Hz power input Note The unit has a dual input power supply which will accept both AC and DC input If both inputs are connected the unit will be powered by AC If AC is disconnec...

Страница 33: ...on of Pins Tab 6 Allocation of Pins Connector Description Pin 01 TxD Transmit Data Negative Pin 02 TxD Transmit Data Positive Pin 03 GND Ground Pin 04 RxD Receive Data Negative Pin 05 RxD Receive Data Positive Pin 06 TxD Transmit Data Negative Pin 07 TxD Transmit Data Positive Pin 08 GND Ground ...

Страница 34: ... by electrical shock Switch off voltage supply if the wires have damaged insulation Only skilled electricians must perform work on the electric system Keep moisture away from live parts Keep the system closed Do not attempt to bypass or disable fuses The allocation of the connectors depends on the configuration Standalone ECDIS NX Compact and the main ECDIS NX Compact in a dual configuration are a...

Страница 35: ...NMEA 1 GPS 1 NMEA 2 GPS 2 NMEA 3 Gyro Compass NMEA 4 Speed Log NMEA 5 Echosounder NMEA 6 BAM NMEA 7 BNWAS only required for use of Track Control System NMEA 8 AIS Allocation of Devices Backup Unit Tab 8 Allocation of Devices Backup Unit Con nec tor Device NMEA 1 GPS 1 NMEA 2 GPS 2 NMEA 3 Gyro Compass NMEA 4 Speed Log NMEA 5 Autopilot CH0 Track Ctrl NMEA 6 Autopilot CH1 ...

Страница 36: ...SB keyboard is connected to the panel PC Support Equipment Bootable USB flash drive with the ECDIS software provided by Raytheon Anschütz Procedure 1 Insert the USB flash drive into the blue USB 3 0 ports of the panel PC 2 Start the panel PC On first start ECDIS NX Compact will ask for the future boot type Fig 19 Select Future Boot Type 3 Select future boot type 2 ...

Страница 37: ...e 4 Remove the USB flash drive Note The USB flash drive must be removed or the subsequent installation will fail 5 Press any key to proceed The system will reboot several times during the installation Do not interrupt the process or switch of power Note This step may take up to 20 minutes ...

Страница 38: ... Window 6 Select the install options Select the configuration ECDIS NX Compact Standalone ECDIS NX Compact Dual MFC1 or MFC2 Select Install VDR Image Service Select if the installation is an ECDIS 24 refit 7 Select the softkey Install 8 Wait for the installation process to finish ...

Страница 39: ...ct the softkey Start ECDIS NX 10 Wait until the Software Deployment Tool is shown in the background before proceeding Fig 23 User Account Control Message 11 Select the softkey Yes to proceed ECDIS NX starts up with a message that states that no valid license for the SevenCs kernel has been found ...

Страница 40: ...ration About this task ECDIS NX Compact must be configured with the Synapsis Service Tool ECDIS NX requires at least the RAn order number in the service tool as this is used to calculate the S63 User Permit which is required to order and use S63 ENC charts To set the RAN order number open the Service Tool load the configuration and navigate to Synapsis Configuration ShipParameters ...

Страница 41: ... last five digits are used The ECDIS NX software needs a 7Cs kernel license in order to operate This license needs to be obtained from 7Cs For obtaining a license a so called license request file needs to be sent to 7Cs and the received license file needs to be installed in the system The steps described in this chapter only work for the initial setup The licensing mechanism for ECDIS NX requires ...

Страница 42: ...ts requires changing the registration permit during the registration process see below Note that activating any additional chart products besides ENC S 57 S 63 requires the purchase of the corresponding additional BST The use of these licenses is monitored To obtain and install a license perform the following steps Procedure 1 Start ECDIS NX 2 When starting the ECDIS NX without a valid license the...

Страница 43: ...rs showing the SevenCs hardware IDs Fig 30 Dialog Hardware IDs 5 Verify that the correct Registration permit is displayed It is possible to change this registration permit which will then be set in the request file The current default permit is RAYTHEON PK1118 RAYTHEON 01 This permit only allows the use of ENCs S 57 S 63 In case additional chart types should be supported the registration permit ne...

Страница 44: ...license information as a file license upd shortly after from their registration server If the licensing robot does not answer as expected the licenses can be requested directly from the 7Cs support support sevencs com 9 Store the received license file on a USB flash drive and plug it into the ECDIS NX Compact while showing the No valid license found dialog Select the softkey Open License File whic...

Страница 45: ...PIN and ARCS User Permit to UKHO customer service CS UKHO Customer Services customerservices ukho gov uk and request the ARCS permits 12 Restart the ECDIS NX Compact 13 If ARCS is used install the received ARCS permits using the ChartHandler in the ECDIS NX 14 Configure the CCRP and sensor positions in the Synapsis Service Tool Results Installation and setting to work is complete ...

Страница 46: ...ECDIS NX Compact 3 Annex 10000000559 36 Edition 001 3 Annex ...

Страница 47: ...Standalone Unit Master Unit in Dual Mode ...

Страница 48: ...Backup Unit in Dual Mode ...

Страница 49: ...ECDIS24 Refit ...

Страница 50: ...LES OF CORRECT CLASSIFICATION AUTHORITY EMV SCHUTZANFORDERUNG SAEMTLICHE GERAETE UND KABEL SOLLEN DEN GROESSTMOEGLICHEN ABSTAND ZU EMV STOERQUELLEN WIE DAUER KURZZEIT UND KNACKSTOERERN HABEN ELECTROMAGNETIC COMPATIBILITY INSTALL UNITS AND CABLES AT GREATEST POSSIBLE DISTANCE TO SOURCES OF INTERFERENCE SUCH AS TRANSIENTS CLICKS NICHT RAYTHEON LIEFERUNG NOT SUPPLIED BY RAYTHEON RAYTHEON LIEFERUNG LA...

Страница 51: ...S 485 7 RS 422 RS 485 8 RS 422 RS 485 24 PANEL PC i7 TOUCH 95 01 HD 24T23REC M64 4F 95 01 MAIN AND EMERGENCY SOURCE OF POWER 230V AC FEEDING FROM TERMINAL STRIP MAIN AND EMERGENCY SOURCE OF POWER 24V DC FEEDING FROM GPS 1 GPS 2 GYRO LOG ECHOSOUNDER BAM BNWAS AIS VDR ALF ALC PHYSICAL DESCRIPTION INTERFACE SIGNAL INFORMATION SIGNAL FROM TO SYNAPSIS DEVICE NMEA 1 IN NMEA 1 OUT NMEA 2 IN NMEA 2 OUT NM...

Страница 52: ...ATIONS OF THE RULES OF CORRECT CLASSIFICATION AUTHORITY EMV SCHUTZANFORDERUNG SAEMTLICHE GERAETE UND KABEL SOLLEN DEN GROESSTMOEGLICHEN ABSTAND ZU EMV STOERQUELLEN WIE DAUER KURZZEIT UND KNACKSTOERERN HABEN ELECTROMAGNETIC COMPATIBILITY INSTALL UNITS AND CABLES AT GREATEST POSSIBLE DISTANCE TO SOURCES OF INTERFERENCE SUCH AS TRANSIENTS CLICKS NICHT RAYTHEON LIEFERUNG NOT SUPPLIED BY RAYTHEON RAYTH...

Страница 53: ...CORE CROSS SPECIFICATIONS ARE MINIMUM RAYTHEON REQUESTS BUT TAKE INTO CONSIDERATION THE SPECIFICATIONS OF THE RULES OF CORRECT CLASSIFICATION AUTHORITY EMV SCHUTZANFORDERUNG SAEMTLICHE GERAETE UND KABEL SOLLEN DEN GROESSTMOEGLICHEN ABSTAND ZU EMV STOERQUELLEN WIE DAUER KURZZEIT UND KNACKSTOERERN HABEN ELECTROMAGNETIC COMPATIBILITY INSTALL UNITS AND CABLES AT GREATEST POSSIBLE DISTANCE TO SOURCES O...

Отзывы: