Compass
STD 22
Installation and Service manual
Compass STD 22 Compact
55
Edition: May 20, 2005
3646/110--233.DOC010302
2.6.4.5
Reading the alignment error
The alignment error must be entered in the table provided for that purpose on the inside
of the cover.
Alignment Error
123.4
Figure 34
: Table at compass cover (inner side)
Switch B37 (DIP switch)
1 2 3 4 5 6 7 8
OPEN
OFF
ON
B38
2X
B39
1X
DIP--switch “8” in “OFF” position.
NOTE:
It is essential to enter this value, because the alignment error will be needed if the sensor
electronics are replaced, in order to determine the reference course for the new PCB.
DIP switch “8” in “ON” position.
The STD 22 Compass is ready for use.
Replace the cover of the compass and screw it tight.
Содержание 110-233
Страница 124: ...Installation and Service manual Compass STD 22 114 Edition May 20 2005 3646 110 233 DOC010302 intentionally left blank ...
Страница 209: ...Installation and Service manual Compass STD 22 Compass STD 22 Compact 2 Edition May 20 2005 3646 110 233 DOC010302 ...
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......
Страница 236: ......
Страница 237: ......