Compass
STD 22
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
185
Edition: May 20, 2005
3646/110--233.DOC010302
1
2
3
4
4
Figure 67
: Dismantled outer sphere (overhead view)
6.1.1.1
Draining the supporting liquid and distilled water
(see Figure 67)
-- Remove the ventilation screw (Figure 67/1) to vent the system
-- Remove the supporting liquid screw (Figure 67/2) so that the supporting liquid can be
poured out
-- Holding the outer sphere with both hands, pour out the supporting liquid and throw it
away (no special measures are needed for disposal).
-- Remove the distilled water screw (Figure 67/3), so that the distilled water can be poured
out. Remove the remaining distilled water from the outer sphere with the injector.