RSSD AR
-
727H MANUAL 5
BOX CONTENTS & INSTALLATION
BOX CONTENTS & INSTALLATION
BOX CONTENTS & INSTALLATION
BOX CONTENTS & INSTALLATION
BOX CONTENTS
4
4
4
4
INSTALLATION
CONNECTOR DIAGRAM
P4
P4
P4
P4
P3
P3
P3
P3
P2
P2
P2
P2
P1
P1
P1
P1
STEPS
NOTICE
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
Table1: CN-3 Colour Coding
Table2: CN-1 Colour Coding
Table4: CN-2 Colour Coding
Table3: CN-4 Colour Coding
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire Application
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Wire
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Colour
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Description
Screw mounting plate to the wall.
Pull cable ends through the access hole in the mounting plate.
Attach controller to the mounting plate and install screw (supplied) into the hole at the
bottom with the allen key (supplied).
Apply power. Sounder will emit a short beep and the green power LED & display will illuminate.
CONDUIT
CONDUIT
CONDUIT
CONDUIT
The communication wires and power line Should Not
Should Not
Should Not
Should Not be housed in the same electrical conduit.
They should always be installed in separate conduit.
CABLE SELECTION
CABLE SELECTION
CABLE SELECTION
CABLE SELECTION
Use twisted pair and
Use twisted pair and
Use twisted pair and
Use twisted pair and Do Not
Do Not
Do Not
Do Not star out.
star out.
star out.
star out. This will cause problems with data to and from the readers.
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
Do Not
Do Not
Do Not
Do Not connect the reader and lock to the same power supply. While the lock is active it can destabilize
the power supply and effect the readers function. The standard connection of the power supply is to
connect the door relay and lock to one power supply and the reader on a separate power supply.
Door Relay
Door/Alarm Relay
Door Sensor
Exit Switch
Alarm Relay
Power
Blue/White
Purple/White
White
Orange
Purple
Grey
Thick Red
Thick Black
1
2
3
4
5
6
7
8
NO 24VDC 1A
NC 24VDC 1A
COM 24VDC 1A
Negative Trigger Input
Negative Trigger Input
NO/NC Optional (By Jumper)
DC Power 12V
DC Power 0V
1
2
3
5
6
7
4
Thick Blue
Thick Green
Thin Green
Thin Blue
Pink
Brown
Yellow
Networking
Wiegand
Buzzer
LED
RS-485 (B-)
RS-485 (A+)
Buzzer Output 5V 100mA, Low
Green LED Output 5V 20mA, Max
Red LED Output 5V 20mA, Max
Wiegand DAT:1 Input
BA Clock Input (W1)
.
Wiegand DAT:0 Input
BA Data Input (W0)
Yellow
Orange
Red
1
2
3
Tamper Switch
Normally Closed
Common
Normally Open
1
2
3
4
off Latch Type
on
Orange/White
Yellow/White
Red/White
Arming Setting Input
Serial Port
Arming Status Output
Card Present
Arming Output (Active Low)
Card Present Output Active Low
(Transistor Output)
Brown/White
Serial Output (Transistor Open
Collector) (4800,N,8,1)
1
1
1
1
2
2
2
2
3
3
3
3
P1
P1
P1
P1
P2
P2
P2
P2
P3
P3
P3
P3
P4
P4
P4
P4
A. Controller
B. User Guide
C. Connection Cables
D. Water Resistant Strip
E. Allen Key & Screws