A-2
Raynger 3i Series Operator’s Manual
FOCUS POINT D:S = 75:1 @15 m (50 ft) FAR FIELD D:S = 68:1
15
10
20
30
5
40
3
6
9
1.5
12
50
0
0
1.3
2.0
5.0
3.5
8.0
33
51
124
6.5
86
165
203
DISTANCE: SENSOR TO OBJECT IN METERS
DISTANCE: SENSOR TO OBJECT IN FEET
IR Spot Diameter at Lens = 23 mm (0.9 in)
Laser Diameter at Lens = 40 mm (1.6 in)
IR Beam Profile
Laser Profile
LTDL2
LTDL3
Spot Diameter (in)
Spot Diameter (mm)
1ML2
1ML3
1MSC
1.5
0.8
0.5
2.3
3.2
80
57
18
13
4.0
36
100
FOCUS POINT D:S = 180:1 FAR FIELD D:S = 140:1
25 mm @ 4.6 m
1.0 IN @ 15 FT
Focus Point
IR Spot Diameter at Lens = 7 mm (0.3 in)
15
10
20
30
5
40
3
6
9
1.5
12
50
0
0
DISTANCE: SENSOR TO OBJECT IN METERS
DISTANCE: SENSOR TO OBJECT IN FEET
Spot Diameter (in)
Spot Diameter (mm)
LTCL2
LTCL3
5000
3000
1500
1000
36
60
120
180
0
0
0.9
1.9
4.6
7.3
23
48
118
FOCUS POINT D:S = 75:1 FAR FIELD D:S = 20:1
0.3 IN @ 24 IN
8 mm @ 610 mm
Focus Point
IR Spot Diameter at Lens = 23 mm (0.9 in)
Laser Diameter at Lens = 40 mm (1.6 in)
IR Beam Profile
Laser Profile
203
DISTANCE: SENSOR TO OBJECT IN INCHES
DISTANCE: SENSOR TO OBJECT IN MILLIMETERS
Spot Diameter (in)
Spot Diameter (mm)
OPTICAL CHARTS
Note that the optical resolution values are stated at minimum 90% energy (95% for 1M).
G5SC
1.0
1.3
Focus Point
1.5 IN @ 75 IN
2.9
4.9
27
32
38 mm @ 1900 mm
74
137
5000
3000
1500
1000
36
60
120
180
0
0
FOCUS POINT D:S = 50:1 FAR FIELD D:S = 30:1
DISTANCE: SENSOR TO OBJECT IN INCHES
DISTANCE: SENSOR TO OBJECT IN MILLIMETERS
Spot Diameter (in)
Spot Diameter (mm)
IR Spot Diameter at Lens = 23 mm (0.9 in)
Figure A-2: Optical Charts
1.888.475.5235
Содержание RAYNGER 3i LTDL2
Страница 2: ...1 888 475 5235 info Raytek Direct com...
Страница 4: ...1 888 475 5235 info Raytek Direct com...
Страница 8: ...Table of Contents Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 12: ...1 4 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 46: ...2 34 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 58: ...A 4 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 66: ...C 4 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 68: ...D 2 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 70: ...E 2 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...
Страница 72: ...F 2 Raynger 3i Series Operator s Manual 1 888 475 5235 info Raytek Direct com...