Programming
Guide
Marathon
Series
FA/FR
43
Description
Char
Format (2)
P
(1)
B
(1)
S
(1)
N
(1)
Legal Values
Factory Default
Wide Power
Q
nnnn.nnn
√
√
0000.000-9999.999
Narrow Power (FR only)
R
nnnn.nnn
√
√
0000.000-9999.999
Slope (FR only)
S
n.nnn
√
√
√
√
0.850-1.150
1.000
Target temperature
FR series: 2-color
T nnnn
√
√
(4)
Temperature unit
U
X
√
√
√
√
C or F
USA: F, Foreign: C
Poll/Burst mode
V
X
√
P = Poll, B = Burst
Burst
Target temperature
FR series: 2-color wide
W nnnn
√
√
(4)
Burst string contents (5)
X$
√
Multidrop address
XA
nnn
√
√
√
000 to 032
000
Low temperature limit
XB
nnnn
√
0000-9999 (4)
set at factory calibration
Deadband (6)
XD
nn
√
√
01 - 55 in °C
02
Decay rate
XE
nnnn
√
√
0000-5555°C
0000
Restore factory defaults (8)
XF
√
√
High temperature limit
XH
nnnn
√
0000-9999 (4)
set at factory calibration
Sensor initialization
XI
n
√
√
√
√
0 = Flag reset
1 = Flag set
1
Laser (optional)
XL
X
√
√
√
0 = off, 1 = on
H = overheat (off)
N = no laser built in
0
Sensor model type
XM
X
√
A, B, C
set at factory calibration
Output current
XO
n
√
√
0=0 - 20 mA, 4=4 - 20 mA 4
Second setpoint
XP
nnnn
√
√
0000 to 5432 (11)
0000
Sensor revision
XR
Xn
√
set at factory calibration
Setpoint / relay function
XS
nnnn
√
√
0000 to 5432 (9)
0000
Trigger XT
n
√
√
√
XT0=inactive, XT1= active
Identify unit
XU
√
!XUFR1A
Sensor serial number
XV
Xnnnnnn
√
set at factory calibration
Hysteresis Advanced Hold
XY
nnnn
√
√
0000-3000°C
0002
Attenuation to activate relay (10)
(FR only)
Y nn
√
√
√
0 to 95%
95%
Attenuation for failsafe (FR only)
Z
nn
√
√
√
0 to 99%
95%
Table
6:
Command
List
(continued)
(4)
in
current
scale
(°C
or
°F)
(5)
see
section
9.3.2
Burst
Mode
,
p.
40
(6)
no
effect
if
relay
in
alarm
mode
(7)
N
=
no
laser
built
in
(8)
Note
that
this
command
has
a
special
effect
on
the
“Bottom
of
mA
range”
parameter,
as
noted
above
in
(6)
(9)
0000
places
unit
in
alarm
mode.
Non
‐
zero
setpoint
value
puts
unit
in
Setpoint
mode.
Setpoint
is
in
current
scale
(°C
or
°F).
Must
be
within
unit’s
temperature
range.
(10)
Relay
goes
to
abnormal,
display
and
analog
out
continue
to
provide
temperature.
(11)
XP
=
000
means
only
1
setpoint
or
no
setpoint
is
used.
XS
<>
0000
and
XP
<>
0000
means
2
setpoints
are
used.
(XS
defines
the
first
setpoint.
XP
defines
the
second
setpoint.)