Switch 

position 

Detection 

Resistance 

Class

Comment 

Left 

(default)

24.9K Ω

6

For use with 802.3bt compliant PSE’s. 

This setting is also compatible with 

most legacy products high power PSE.

Central 

24.9K Ω

4

Compatible with legacy single signature 

high power PSE using class 4 power 

negotiation.

Right

12.5 K Ω

4

Compatible with Phihong non standard 
high power PSE.

For further information regarding the compatibility check with the supplier of your 
PSE equipment.

To change the switch setting, turn OFF the power to the illuminator, remove the 
baseplate and access the switch as shown.

Detection Resistance Selection Switch

Baseplate fixing screws: Torque 0.6Nm

Содержание VARIO2 series

Страница 1: ...Waterproof RJ45 connector Accessories optional 80 x 30 beam angle IHD 120 x 50 beam angle IHD System requirements A PC running Windows with network access running a modern web browser Full detailed in...

Страница 2: ...diation emitted from this product May be harmful to eyes do not stare at the lamp For VAR2 IPPOE w4 1 VAR2 IPPOE w8 1 and VAR2 IPPOE w4 2 variants hazard distance is 1500mm For VAR2 IPPOE w4 3 VAR2 IP...

Страница 3: ...e for Data and Optional PoE Photocell The illuminator has a photocell for automatic day night switching and has an External Input to act as a telemetry trigger input volt free or TTL and an External O...

Страница 4: ...external output wires as required IMPORTANT Ensure PoE equipment or 24V PSU are suitably rated For 8 sized products check PoE detection resistance is set correctly Ensure Cat 5 cable and auxiliary ca...

Страница 5: ...We recommend Raytec DiscoMan Tool as the easiest way to establish communication If using IP address for direct communication illuminator and computer must be in same network range STEP 5 Illuminator...

Страница 6: ...oE device as follows The Factory Software version of the illuminator is shown by characters 4 5 6 in the product serial number The CAT5 cable is both the power and data connection for the illuminator...

Страница 7: ...ce Selection Switch There is a 3 way switch on the VAR2 IPPoE w8 1 i8 1 and i8 1 C illuminators which can be used to change the PoE detection resistance and the PD class of the illuminator 24 9K and P...

Страница 8: ...Central 24 9K 4 Compatible with legacy single signature high power PSE using class 4 power negotiation Right 12 5 K 4 Compatible with Phihong non standard high power PSE For further information regard...

Страница 9: ...m of the product and remove the existing lens and then re attach the baseplate securely With no lens insert the product produces a 10o beam angle To alter to any other angle remove the existing lens a...

Страница 10: ...fitted to unit Use for alternative power 24V DC if required Use for connecting external input and external output as required To maintain the IP rating of the product any cable not in use must be wat...

Страница 11: ...OPTION 1 Raytec DiscoMan Tool We recommend the easiest and fastest way to identify and connect to illuminators is using the Raytec DiscoMan Tool where the IP address can be altered DHCP enabled as sta...

Страница 12: ...pability Note If assigning the IP address fails check that there is no firewall blocking the operation and that the computer and illuminator have IP addresses in the same range Raytec DiscoMan Tool Ba...

Страница 13: ...ng name software version model and the time the illuminator has been powered Hierarchy of Photocell vs Telemetry If the telemetry function is enabled then the photocell must detect that it is dark for...

Страница 14: ...al or VMS Local To operate the illuminator via a VMS or third party application that uses the Raytec API then the illuminator mode should be set to VMS or VMS Local In VMS mode the illuminator will ig...

Страница 15: ...dard Setup Factory Defaults The illuminator is operating in Local mode and will respond only to its own photocell and telemetry status By default the illuminator is NOT assigned to a group The illumin...

Страница 16: ...Photocell Only Active State Short Circuit Low External Input Type of Input Volt Free Active State Short Circuit Low Photocell Photocell Sensitivity 20 lux Basic Web Page Functionality All web pages h...

Страница 17: ...by VMS or HTTP commands Adv Settings Allows for further detailed setup of External Input External Output Photocell sensitivity level and duration of Override Access Change passwords Network Allocate I...

Страница 18: ...of our model names the size of the illuminator details box to the right has been increased If you have previously used a Vario IP PoE on your machine your browser will have remembered the old style a...

Страница 19: ...VARIO2 IPPOE unit see page 7 for required ratings Check connection and wiring of CAT5 6 cable to VARIO2 IPPOE Verify link has been established with the router switch to which the illuminator is conne...

Страница 20: ...teccctv com Raytec Ltd Unit 15 Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom Raytec Americas Tel 1 613 270 9990 ussales rayteccctv com Raytec Systems Inc 800 3...

Отзывы: